IOM/KPDS/NOV 19/00
Page 14
14
14
14 of 50
50
50
50
Issue Date : 22/11/2019
Revision: 00
10.6 Fit adapter to casing cover and tee joint to bearing spider (if applicable). Connect
the transmission bearing flushing pipe to adapter with the help of nuts. (Applicable
if transmission bearing lubrication is external clear compatible liquid, otherwise fix
plug to the casing cover).
10.7 Fix the clamp to the bottom column pipe (13301).
10.8 Lift the unit vertically with the help of slings and chain pulley block. While lifting
take care that no part of the pump is being dragged against the floor.
10.9 Put two girders or strong wooden logs across the opening of the tank in which
pump is to be fitted. Rest the clamp while erecting the pump. Lower the unit till the
clamp rests on the girders.
10.10 Press the intermediate bearing bush (35100) in bearing spiders (24500) then drill
and tap (M6x10L) one hole at the junction of bush and bearing spider. Fit one grub
screw in the tapped hole to avoid the rotation of bush (This is required in case of
replacement of bush only). Mount cover (27801) on bearing spider with the help of
screws. Fix non-metallic screw on bearing spider to avoid the rotation of bush.
10.11 Mount bearing spider (24500) on the bottom column pipe (13301).
10.12 Mount standard column pipe (13302) on bearing spider (24500). Fix it with the help
of screw and nuts. Tighten the diametrically opposite nuts one by one. Fix three
way pieces to the bearing spider (24500) and connect the flushing pipe coming
from casing cover (22000). Also fix one more flushing pipe to another end of three
way piece with the help of sealing nut.
10.13 Apply thread compound liberally inside the screwed coupling (39500) fitted on
the pump shaft and threaded portion of intermediated shaft (18400). Fit the
successive screwed coupling in to intermediate shaft (18400) and intermediate
shaft in to the screwed coupling already fitted on the pump shaft (18600).
10.14 Lift the column pipe (13302) with the help of another clamp.
10.15 Lower the standard column pipe (13302) and fix to the lower column pipe (13301)
with the bearing spider in between. Tighten the diametrically
opposite nuts one by
one.
Summary of Contents for KPDS
Page 35: ...IOM KPDS NOV 19 00 Page 32 32 32 32 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 36: ...IOM KPDS NOV 19 00 Page 33 33 33 33 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 37: ...IOM KPDS NOV 19 00 Page 34 34 34 34 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 38: ...IOM KPDS NOV 19 00 Page 35 35 35 35 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 39: ...IOM KPDS NOV 19 00 Page 36 36 36 36 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 40: ...IOM KPDS NOV 19 00 Page 37 37 37 37 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 42: ...IOM KPDS NOV 19 00 Page 39 39 39 39 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 43: ...IOM KPDS NOV 19 00 Page 40 40 40 40 of 50 50 50 50 Issue Date 22 11 2019 Revision 00...
Page 44: ...IOM KPDS Issue Date 10 08 2007 Page 41 of 50 Last Revision 20 07 2017...
Page 45: ...IOM KPDS Issue Date 10 08 2007 Page 42 of 50 Last Revision 20 07 2017...
Page 46: ...IOM KPDS Issue Date 10 08 2007 Page 43 of 50 Last Revision 20 07 2017...
Page 47: ...IOM KPDS Issue Date 10 08 2007 Page 44 of 50 Last Revision 20 07 2017...