![KIRLOSKAR 65-DSM 315M Instruction On Installation, Operation And Maintenance Download Page 33](http://html1.mh-extra.com/html/kirloskar/65-dsm-315m/65-dsm-315m_instruction-on-installation-operation-and-maintenance_1972124033.webp)
5
3.4 During stopping the pump:
3.4.1 Close the valve on delivery side.
3.4.2 Stop the motor.
3.4.3 If the pump is not required to be operated for a long time, then drain the casing
completely.
4. TECHNICAL DATA:
4.1 Direction of rotation
The standard direction of rotation is clockwise when viewed from driving end. The pump
suitable for anticlockwise rotation can also be supplied against specific requirements.
4.2
pumps are supplied suitable for speed of 1450 rpm. Please contact supplier if the
pump is to be used for higher speeds.
4.3 Bearings
The shaft is supplied with below bearings
6.2
BEARING DETAILS
:
BEARING No.
(SKF OR EQUIVALENT)
Sr.
No.
PUMP TYPE
DE
NDE
01
02
DSM 100-36
DSM 125-40
6307
6309
3307
3309
Designations of bearings are as per SKF catalogue. However, equivalent bearings in type,
capacity and dimensions are also used.
4.4 Lubrication
4.4.1 Type of lubricant – The bearings is grease lubricated.
4.4.2 Quantity of grease – 200 gm
4.4.3 Refilling period – After 1000 hours of running.
4.4.4 Bearing temperature – The permissible bearing temperature rise is 40°C above
ambient temperature
4.4.5 Grades of recommended grease-
Summary of Contents for 65-DSM 315M
Page 15: ...14 CROSS SECTION ASSEMBLY OF DSM 1E CCW CROSS SECTION ASSEMBLY OF DSM 2E CCW...
Page 17: ...16...
Page 18: ...17 CROSS SECTIONAL ASSEMBLY OF DSM 3ME CCW NOTE ALSO FOR DSM 3 3 ME...
Page 29: ...1...
Page 30: ...2...
Page 43: ...15 7 1 2 NON THRU BORE TYPE PUMP Mechanical seal type...
Page 46: ...18...
Page 47: ...19...
Page 48: ...20...
Page 49: ...21...
Page 50: ...22...
Page 51: ...23...
Page 52: ...24...
Page 53: ...25...
Page 54: ...26...