Troubleshooting
Sr.
No
Problem
Probable cause
Action
1
2
3
4
5
6
7
Leakage through cleaner
Rotor does not rotate
Rotor does not rotate even
after cleaning nozzles
Rotor rotates but at low
Speed
Rotor speed very low
or even rotor does not
rotate
Abnormal vibrations of
centrifuge cleaner
Cleaner does not collect
any dirt
Rectangular rubber ring
damage
Nozzles blocked
Entry valve blocked
Leakage of oil through rotor
assembly.
Rotor filled with dirt
completely
Bushes damaged
permanently
Mismatch between arrow
marks on rotor cover and
rotor
Rotor not rotating at desired
speed
Change rubber ring.
Open rotor and clean nozzles
Thoroughly.
Re-assemble the cleaner.
Do not open entry valve
assembly. It requires special
tools Contact your Distributor.
Open rotor and ensure that the
rubber ring has taken proper
seat on rotor body. Then
re-assemble the rotor.
Time for cleaning the rotor
Ensure that the rotor is free on
Shaft. Else replace entire rotor
Assembly.
Open rotor and reassemble it
properly.
See point 2 & 3.
Consult your Distributor.
5.2
Maintenance of Fuel System
5.2.1 Cleaning Fuel Strainer
•
Close fuel stop cock.
•
Remove special banjo bolt situated at the bottom at the Inlet of feed pump.
•
Takeout screw with strainer fitted inside banjo bolt (Fig.5.2.1).
Fig 5.2.1
•
Clean the strainer with clean diesel.