background image

13. SKETCH MAP

IG2600h

IG2600h

                       

 movement state 

IG2600h placed state 

Fuse

Summary of Contents for Sinemaster IG2600

Page 1: ...S I N E M A S T E R DIGITAL INVERTER GENERATOR IG2600 IG2600h WUXI KIPOR POWER CO LTD R R Fuse...

Page 2: ......

Page 3: ...or equipment damage if instructions are not followed NOTE Gives helpful information If a problem should arise or if you have any questions about the generator consult an authorized dealer Our generato...

Page 4: ...13 SKETCH MAP IG2600h IG2600h movement state IG2600h placed state Fus e...

Page 5: ...Pre operation Check 5 Starting the Engine High altitude operation 6 Generator Use 7 Stopping the Engine 8 Maintenance 9 Transporting Storage 10 Troubleshooting 11 Specifications 12 Electric diagram 1...

Page 6: ...sumption g kW h Lube oil Single cylinder 4 stroke OHC gasoline engine 171cc 66x50mm 8 5 1 3 3 3600 T C I WR7DC Recoil starter Automotive unleaded gasoline 500 CD grade or SAE10W30 15W 40 Fuel tank cap...

Page 7: ...on monoxide Never run the generator in an enclosed area The muffler becomes very hot during operation and remains hot for a while after stopping the engine Be careful not to touch the muffler while it...

Page 8: ...rate the generator on a level surface If the generator is tiled fuel spillage may result Know how to stop the generator quickly and understand operation of all the controls Never permit anyone to op e...

Page 9: ...to a suitable container c With the drain screw loosened remove the spark plug cap and pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump d Turn the engine switch to the OFF po...

Page 10: ...Do not overfill the tank there should be no fuel in the filler neck Do not operate the generator while it is on a vehicle Take the generator off the vehicle and use it in a well ventilated place Avoi...

Page 11: ...1 Remove the four M5 screws and remove the muffler protector 2 Remove the muffler the spark arrester and the muffler gasket 3 Use a brush to remove carbon deposits from the spark arrester screen 4 Ch...

Page 12: ...ly tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range OFF Note Smart throttle system does not operate Engine speed is kept over rat...

Page 13: ...vel is below the end of the dipstick refill the recommended oil up to the top of the oil filler neck 1 Check the engine oil level WARNING Using nondetergent oil or 2 stroke engine oil could shorten th...

Page 14: ...asoline mixture or dirty gasoline Avoid getting dirt dust or water in the fuel tank After refueling tighten the fuel filler cap securely Note Note Please dispose of used motor oil in a manner that is...

Page 15: ...Reinstall the left side maintenance cover and tighten the cover screw securely Make sure to turn the engine switch and the fuel cap lever OFF before draining CAUTION Check the air cleaner element to b...

Page 16: ...eplace if necessary 3 1 Log hours of operation to determine proper maintenance 2 Service more frequently when used in dusty areas 3 These items should be serviced by an authorized dealer unless the ow...

Page 17: ...l cap lever choke and the engine switch are OFF when stopping transporting and or storing the generator CAUTION NOTE Do not use the choke when the engine is warm or the air temperature is high 4 Pull...

Page 18: ...ealer perform these carburetor modifications Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 305m 1 000 feet increase in altitude The affect of altitud...

Page 19: ...ttage of all appliances con nected must be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit This could cause the damage t...

Page 20: ...ng that continuously lights the over load indicator light red may damage the generator Marginal overloading that temporarily lights the over load indicator light red may shorten the service life of th...

Page 21: ...ator light red stays on consult your generator dealer NOTE The DC receptacle may be used for charging 12 volt automotive type batteries only the zero load voltage is 15V 30V In DC operation turn the S...

Page 22: ...oad indicator light red and the output indicator light green may light together for a short time about 4 sec but this is no abnormality After start of the equipment the overload indicator light red wi...

Reviews: