Overload Indicator Light (Red)
Output Indicator Light (Green)
Charging Cable
Output and Overload Indicators
The output indicator light(green) will remain ON during normal operating conditions.
If the generator is overloaded(in excess of 2.6kVA), or if there is a short in the con-
nected appliance, the output indicator light(greer) will go OFF, the overload indica-
tor light(red) will go ON and current to the connected appliance will be shut off.
Stop the engine if the overload indicator light (red) comes ON and investigate the
overload source.
Before connecting an appliance to the generator, check that it is in good order,
and that its electrical rating doe not exceed that of the generator. Then connect the
power cord of the appliance, and start the engine.
NOTE
When an electric motor is started, both the overload
indicator light(red) and the output indicator light (green)
may go on simultaneously. This is normal if the over-
load indicator light(red) goes off after about four (4)
seconds. If the overload indicator light (red) stays on,
consult your generator dealer.
NOTE
The DC receptacle may be used for charging 12 volt automotive-type batteries
only, the zero load voltage is 15V-30V.
In DC operation, turn the Smart throttle switch to the
OFF position.
1.Connect the charging cables to the DC receptacle of the generator and then to the
battery terminals.
W A R N I N G
To prevent the possibility of creating a spark near the
battery, connect charging cable first to the generator,
then to the battery. Disconnect cable first at the battery.
Before connecting charging cables to a battery that is
installed in a vehicle, disconnect the vehicles grounded
battery cable. Reconnect the vehicle's grounded bat-
tery cable after the charging cables are removed. This
procedure will prevent the possibility of a short circuit
and sparks if you make accidental contact between a
battery terminal and the vehicle's frame or body.
Do not attempt to start an automobile engine with the
generator still connected to the battery. The generator
may be damaged.
Connect the positive battery terminal to the positive
charging cord. Do not reverse the charging cables, or
serious damage to the generator and/or battery may
occur.
CAUTION
Fuse