Periodical inspection and maintenance are very important for keeping your
generating set in best working condition.
Be sure to shut down the set before performing maintenance, however, if It is
necessary to run the set, good ventilation must be provided, for the exhaust
contains poisonous carbon monoxide.
7. MAINTENANCE
Note:
(1) Shorten maintenance intervals if the generating set operated in dirty area.
(2) The above-mentioned items must be performed with the assistance of KIPOR
dealer.
Recommend engine oil: Engine oil for 4-
stroke gasoline engine SE, SF engine oil
classified by API or SAE10W-30 engine
oil which same as SG grade.
Use SAE10W-30 engine oil when the
temperature is below 10
.
Use SE, SF engine oil classified by API
or SAE5W-30 engine oil which same as
SG grade when the temperature is
below -15
.
7-1 Replace engine oil
4. Refill engine oil until the upper limit
level of the oil filler cap.
1. Open oil filler cap.
2. Loose drain screw plug to drain off
engine oil.
3. Reassemble the drain screw plug.
5. Reassemble the oil filler cap.
Fuel tank
Oil pipes
Each
year or
300 Hrs.
Each
use
First
month or
20 Hrs.
Every 3
months or
50 Hrs.
Every 6
months or
100 Hrs.
Check
Clean
Engine oil
Air cleaner
Fuel strainer
cup
Spark plug
Air valve
clearance
Cylinder head
cover
Check
Replace
Check
Clean
Clean
Clean
Adjust
Clean
Adjust
Clean
(2)
(2)
Item
Maintenance
Time
-
-
-
-