Carbon monoxide hazards

Exhaust contains poisonous carbon monoxide, a colorless and odorless 
gas.Inhaling exhaust can cause loss of consciousness and lead to death.
If you run the generating set in unventilated or confined place, the air you 
breathe could contain a dangerous amount of exhaust gas. So, be sure to 
keep the good ventilation to prevent the exhaust gas from building up.

Operator
Responsibility:

For the safety of the operator and others, be sure  to operate the 
generating set carefully.

Know how to stop the generating set quickly in case of emergency. Master 

the usage and connection procedures of all generating set controllers, 

output receptacles. Be sure that the operator must receive proper 

instruction. The children or the pets are forbidden to close to the generator.

The operation including installation, running and maintenance should be 

done by professional people who know well about the feature of generator.  

Fire and burn hazards

The exhaust gets hot enough to ignite some materials. The gen-erating set 
must be kept at least 1 meter away from buildings and other equipments.
Keep flammable materials away from the generating set. Be sure to service or 
store the generating set in doors after the engine cooled.
The fuel is flammable and fuel vapor can explode. Refuel in a well-ventilated 
place with the engine stopped. Keep the flames and sparks away, and do not 
smoke in the area.
Fuel may spill and ignite if the generating set is tilted or overturned. Place the 
generating set on a firm, level surface. Avoid loose sand or snow.
It is limited to use the generator in the high-hazard risk area.
Some  parts of the explosive motor are very hot. Failure to operate could lead 
to burn. Please note the warning stickers on the generator.
Operators should have self-protection awareness when operating generator, 
please wear sound-proof ear shield, insulating boot and insulating gloves.
The key of door lock and electric door accessories for meter door and 
maintenance door should be well kept by operators. Please lock the doors of 
generator tightly to prevent somebody to operate (the children can not realize 
the danger).

WARNING

WARNING

Electric shock hazards 

The generating set will produce enough electric current to cause a serious 
shock or electrocution if misused. Running the generating set in the wet 
places such as rain, snow, swimming pool or sprinkler system, or when your 
hands are wet, could result in electrocution. Do not connect to the building's 
power system without installation of the isolation switch performed by a 
qualified electrician.

WARNING

1. SAFETY INFORMATION

4. KDE16EA3, 

KDE19EA3

Electrical wiring diagram of 

36

Summary of Contents for KDE16EA

Page 1: ...DIESEL GENERATING SET R WUXI KIPOR POWER CO LTD R KDE16EA K DE16STA KDE19EA K DE19STA KDE16EA3 K DE16STA3 KDE19EA3 K DE19STA3 Single phase Three phase...

Page 2: ......

Page 3: ...ore use Keep any sources of ignition away from engine KDE16EA KDE16EA We reserves the right to make changes at any time without notice and without incurring any obligation No part of this publication...

Page 4: ...ul information is provided To ensure the safety and durability be sure to obey to this manual To ensure the safety of the operator and others be sure to correctly operate and carefully manage your gen...

Page 5: ...d coefficient C Relative humidity 30 Note When the relative humidity is 60 the modified coefficient is C 0 01 When the relative humidity is 80 the modified coefficient is C 0 02 When the relative humi...

Page 6: ...n calculate the value of the potential e The relations among of the allowable current and length section of the Insulating cable single core multi core are as follow Presume that the use voltage is 22...

Page 7: ...ne cooled The fuel is flammable and fuel vapor can explode Refuel in a well ventilated place with the engine stopped Keep the flames and sparks away and do not smoke in the area Fuel may spill and ign...

Page 8: ...ling air outlet Exhaust outlet Lifting hook Fuel filler cap Emergent stop button Operation panel Grounding bolt Connection pole Fuel drain outlet Engine oil drain outlet Overflow pot Engine oil drain...

Page 9: ...3 2 2 Control panel Fuel Meter Fuse Breaker Smart Display Starter Switch Starter switch starter starter 34 2 KDE16STA3 KDE19STA3 Electrical wiring diagram of...

Page 10: ...ic shock If need to replace please replace one that has equal degree and performance Fuel 2 4 Fuel Meter 2 3 Circuit Breaker Indicator Fuel meter 33 1 Electrical wiring diagram of KDE16STA KDE19STA 10...

Page 11: ...verload P 05 Start trouble P 06 Emergency indicator P 07 Charging trouble P 08 Generator overheating PRE H Preheating indicator START Start indicator Screenoption Phasesequence switching Start Back St...

Page 12: ...evel it is not the judging standard for whether applying noise protection Factors affect the practical noise level include the ambient condition and other noise source such as the quantity of working...

Page 13: ...7 3 PRE RUNNING CHECK Maintenance door 30 Is the electric door lock on Turn the electric door lock on 8 TROUBLESHOOTING ing agent...

Page 14: ...oil before operating the generating set after storage 4 Fill the fuel tank with fresh diesel fuel 5 Disconnect the battery ground cable from the terminal and tape it While storing the battery fully ch...

Page 15: ...9 3 2 Fuel 28 7 TRANSPORTING AND STORAGE 7 1 Transporting Handle Handle Lifting hook...

Page 16: ...il from generator must be stored in container To deal with bad matter such as fuel oil cooling water solvent filter and battery according to the law 27 agent 6 5 Replace the Fuse Turn the key of elect...

Page 17: ...l the r up to the MAX mark with the engine cold overflow pot 3 If there is no in the check whether the cooling system has leadage and service it if necessary Be sure that there is coolant in the radia...

Page 18: ...d in oil usually the fuel water separator can separate the water and settled the cup base So need to change regularly Loose the drain water bolt the water will drain form the rubber conduit and drain...

Page 19: ...t need maintenance and filling liquid Observe the status displays of battery Blue the battery is in good condition White the electricity is not enough need to charge Red the electrolyte is not enough...

Page 20: ...back to ON position automatically 3 Smart panel control can preheat automatically when start the time can be set 4 START AND SHUTOFF THE ENGINE 4 1 Break in Period initial 50 hours 4 2 Start the Engin...

Page 21: ...l KDE19STA3 Model KDE16STA3 50 60 50 60 Three phase Terminal Three phase Terminal Three phase Terminal Recep tacle Recep tacle Recep tacle Recep tacle 13 5 10 8 6 4 0 1 1 1 8 2 5 3 1 15 5 12 10 8 6 4...

Page 22: ...Turn the breaker to OFF 3 Close the electric door lock Turn the key of electric door lock to OFF 4 3 Shutoff the Engine Electric Start Key OFF ON START 21 Model Frequency Hz One circuit kVA Two circu...

Page 23: ...ING SET 5 1 Connecting to a Building s Power Supply System 20 Model Frequency Hz One circuit kVA Two circuit used kVA Three circuit used kVA 50 7 2 10 8 10 8 60 8 3 12 4 12 4 50 8 7 13 13 60 10 1 15 2...

Page 24: ...he connection wiring box cover and connet the cable to terminal U V and W Using terminals U V W N 2 Close the connecting box cover and tighten the bolts 3 Start engine Examine the generator three phas...

Reviews: