39
7.1.6
CFG message: Geovane’s current configuration
$GVCFG,00,3,1,0,1,0*60
<
CR
><
LF
>
Field
Example
Description
Start character
$
Talker identification
GV
Geovane identification
Message ID
CFG
Identifier associated to the type of
message
Listener identification
00
Current Listener identification
Measurement rate
3
Current measurement rate:
1 = 1 second
2 = 5 seconds
3 = 10 seconds
4 = 30 seconds
5 = 60 seconds
Digital output on/off
1
Current digital output status:
0 = Disabled (Input messages are
always enabled)
1 = Enabled
Frequency output on/off
0
Current frequency output status:
0 = Disabled
1 = Enabled, True North offset
Analog #1 output on/off
1
Current analog #1 output status:
0 = Disabled
1 = Enabled, True North offset
2 = Enabled, Tilt X
3 = Enabled, Tilt Y
Analog #2 output on/off
0
Current analog #2 output status:
0 = Disabled
1 = Enabled, True North offset
2 = Enabled, Tilt X
3 = Enabled, Tilt Y