Undo the 3 screws to open the terminal ports and insert the two Plugs and ground wire(s) into their
respective screw terminals as shown in photo (3) on page 4. The Red wire is plugged into the (left)
terminal. The Shield is plugged into the middle terminal and the black ground wire/s (from the shielding
and/or bridge –and/or- the central ground point, as the case may be) into the remaining terminal (right).
Tighten the screws firmly but not too tightly.
NOTE:
I do not advocate Star grounding, in fact it can cause headaches. Bear in mind all shielding and
ground wires should be somehow connected (either directly or indirectly) to the right hand port of the
Connector-block. This includes the control cavity shielding and output cavity shielding (if present). Since it
is
not
recommended to insert more than 2 wires into the connector-block ports all these elements can be
connected together at another point and a single wire leading from that point to the right hand port of the
connector-block.
CAUTION
:
Failure to ground any shielding will result in excessive unwanted noise.