09
Attaching the Connection Kit
Step Eight
(return connection)
1. Assemble and connect end fittings (Male connection A,
Tee connection G & Air bleeding valve E)
2. Open lid on left hand end tube fitting
3. Place rubber seal (D) on male end of collector area
(blocking lower chamber) This applies to DF only -
please discard seal for HP
4. Secure in position with clip (F)
5. Ensure clip (F) legs protrude out of bottom
of enclosure
6. Complete and attach technical label (I)
7. Close lid and secure with screw
E
G
A
A
B
F
I
D
(DF ONLY)
F
I
A
B
C
D
E
F
G
H
I
Step Nine
(flow connection)
1. Assemble and connect end fittings (Female
connection B, Tee connection G & Temperature
sensor pocket H)
2. Remove securing pin from female end of
collector
3. Place rubber seal (C) in female end of collector
area (blocking upper chamber) This applies to
DF only - please discard seal for HP
4. Secure in position by relocating securing pin
B
G
H
C
D
C
(DF ONLY)
A
B
C
D
E
F
G
H
I
Sensor must
be fitted on
flow side of
collector.
See diagram
for step 7