Varisol Installation Manual
26
Technical Specifications
* With DF models, a secondary heat dissipation circuit is recommended
Max. Number of Tubes
150
150 150
Dimensions/ tube
Absorber Area (m
2
)
0.100
0.100 0.100
Width of Manifold (mm)
70.9
70.9
70.9
Length (tube and manifold) (mm)
1950
1955
1955
Depth (mm)
70.9
70.9
70.9
Aperture Area (m
2
)
0.105
0.106 0.106
Fluid Volume (ltr)
0.19
0.05
0.05
Inlet and Outlet Dimensions (mm)
22
22
22
Weight (empty) (kg)
2.2
2.13
2.13
Mounting
Recommended Inclination (˚)
0-90
20-70
20-70
Performance Data
Efficiency
Based on Aperture
Based on Aperture
Based on Aperture
eta 0
0.783
0.76
0.78
a
1
(W/m
2
K)
1.061
1.621 2.112
a
2
(W/m
2
K
2
)
0.023
0.008 0.006
IAM (50˚)
0.96
0.96 0.96
η
cal (40k, 1000W)
0.704
0.682 0.686
Solar Keymark Licence Nos
011-751238F 011-751936R
011-751935R
Operating Data
Flow Rate (L/min)
Rated/ tube
0.1
0.1
0.1
Minimum/ tube
0.067
0.067
0.067
Maximum/ tube
0.25
0.25
0.25
Maximum Operating Pressure
6 Bar
6 Bar
6 Bar
Stagnation Temperature (˚C)
240
100
192
Heat Transfer Fluid
Water/Glycol
Water/Glycol
Water/Glycol
Max. Load [kN/m
2
]
(DIN 1055-5)
2.5
2.5
2.5
Materials
Absorber
Copper
Copper Copper
Coating
Selective Coating
Selective Coating
Selective Coating
Absorbance (%)
95
95
95
Emissivity (%)
5
5
5
Mounting Frame and Clips
Stainless Steel,
Stainless Steel,
Stainless Steel,
Aluminium,
Aluminium,
Aluminium,
EPDM
EPDM EPDM
Glass
Low Iron
Low Iron
Low Iron
- Transm. 0.92
- Transm. 0.92
- Transm. 0.92
Vacuum
<10-6mbar
<10-6mbar <10-6mbar
Temperature Limitation
None*
90
135
Quality Certification/ Yes
Yes Yes
Solar Keymark
HP90
HP135
DF
Summary of Contents for Varisol DF