012696 GL0011P-07
– Installation Guidelines for BioDisc BA, BAx, BB & NB Units
Page 10
Control Panel Installation
4.1
General Installation
4.1.1
The control panel need not be adjacent to the plant. It can be wall mounted or fixed to the mounting
frame (available separately). It should be positioned so it cannot be reached by someone standing in
or on the BioDisc unit.
4.1.2
The control panel should be fitted by a qualified electrician working to the latest IEE Regulations.
4.2
Mounting Frame Installation (where applicable)
4.2.1
Set the frame legs in a concrete base, minimum 250mm thick and prop the frame to prevent
movement until the concrete has set.
4.2.2
Allow 350mm minimum clearance from finished ground level to the bottom of the panel.
4.3
Installation of Control Panel
Figure 1 : Control Panel
4.3.1
Remove the four screws on the front of the panel and remove the main cover.
4.3.2
Remove the four screws holding the safety cover and remove the safety cover.
4.3.3
Remove the two screws holding the isolating cover and remove the isolating cover.
4.3.4
Using a suitable M20 gland, feed the mains power supply through Gland Hole 1 (Figure 1). Wire the
mains supply to the terminal blocks following the guide on the connections.
4.3.5
Replace the isolation cover and screws.
4.3.6
Using a suitable M20 gland, feed the motor power supply cable through Gland Hole 4 (Figure 1) and
terminate to connections 5 & 6 (TB3) following the guide on Table 2.
1
2 3 4
5
6 7 8
9
Main Cover
Isolating Cover
Safety Cover