11
ULTRASTEEL PLUS SOLAR
UNVENTED
INDIRECT TWIN COIL CYLINDER
UPPER COIL
The upper coil is connected to the fossil fuel boiler as per the
instructions for the ULTRASTEEL PLUS Unvented Indirect
single coil model with the dual stat control and high limit
thermostat inserted into pocket
G1 (lower diagram page 12).
The wiring requirements are as depicted on page 12-14.
LOWER COIL: SOLAR INSTALLATION
The flow and return from the solar heat source are to
be connected to the indirect coil. Either primary coil
connection may be utilised as the flow or return. The solar
primary circuit must have its own dedicated circulating
pump, thermal and safety controls which must be installed
as per the solar manufacturers instructions. The solar
control system used must be of the solar differential control
type and should be connected to the solar sensor.
The solar sensor, supplied as part of the solar controls
should be inserts into Pocket G1 and is held in-situ with the
black sensor pocket retaining bung provided.
It is necessary to connect the solar pump via the over-
temperature high limit cut-out (provided) Iinto dry stat
pocket G2 to ensure the heat input to the solar coil is
interrupted if the cylinder overheats. Some method
to prevent thermosyphoning must also be employed.
Non-return check valves in the primary flow and return
pipework would be acceptable. If solar controls do not offer
appropriate isolation a 2 port zone valve (not supplied) can
be used with the pump and high limit stat as shown on page
12.
G2
D2
F
B
G1
D1
E
C
D2
A
D1
Code
Designated
Solar
Volume (L)
Fossil Fuel
Volume (L)
Immersion
Heaters
(3kW)
Solar Coil
Surface Area
(m2)
Fluid Content
(L)
AUXSN180
99
76
1
0.760
4.21
AUXSN210
119
82
1
0.860
4.75
AUXSN250
124
119
1
0.860
4.75
AUXSN300
124
161
1
0.960
5.28
Boss centre from floor
ErP
Code
Capacity
(Ltrs)#
Height
(mm)
Diameter
(mm)
A
(mm)
B
(mm)
C
†
(mm)
D1
(mm)
D2
(mm)
E
(mm)
F
*
(mm)
G1
(mm)
G2
(mm)
ErP
Rating
Standing
Loss, W
AUXSN180
175
1367
550
530
1021
910
345
855
989
NF
400
1021
C
65
AUXSN210
201
1557
550
530
1087
960
375
905
1055
1022
430
1087
C
76
AUXSN250
242
1802
550
530
1332
1030
375
975
1300
1267
430
1332
C
87
AUXSN300
285
2072
550
530
1584
1060
410
1005
1552
1519
465
1584
C
91
* Not always fitted refer to table above
# AT 3.0 Bar
† Not to be used as the primary heat source
KINGSPAN ALBION
RELIABLE HOT WATER CYLINDERS