![Kingspan AUXD120 Installation And Maintenance Instructions Manual Download Page 11](http://html1.mh-extra.com/html/kingspan/auxd120/auxd120_installation-and-maintenance-instructions-manual_1970995011.webp)
10
ULTRASTEEL PLUS INDIRECT
TECHNICAL SPECIFICATIONS
Technical specifications
Connections:
A
22mm Cold feed with dip pipe to
diffuser in bottom of cylinder
B
22mm Hot water outlet
C1
†
Immersion
heater
C2
*
Secondary immersion heater
D
22mm Coil connections
E
1
/
2
” Temperature relief valve boss
(Valve factory fitted to cylinder)
F
*
22mm Secondary return
B
F
C2
C1
D
A
E
Code
Heat Up Time
(Minutes)
Coil Rating
(kW)
Immersion
Heaters
(3kW)
AUXN120
21
14.44
1
AUXN150
24
16.85
1
AUXN180
27
16.88
1
AUXN210
31
17.08
1
AUXN250
33
20.31
2
AUXN300
42
19.61
2
Boss centre from floor
ErP
Code
Capacity
(Ltrs)#
Height
(mm)
Dia.
(mm)
A
(mm)
B
(mm)
C1
†
(mm)
C2
*
(mm)
D
(mm)
E
(mm)
F
*
(mm)
ErP
Rating
Standing
Loss, W
AUXN120
119
997
550
455
651
355
NF
315
619
NF
B
49
AUXN150
149
1183
550
455
837
385
NF
345
805
NF
B
52
AUXN180
178
1367
550
490
1021
415
NF
375
989
NF
C
65
AUXN210
205
1557
550
490
1087
415
NF
375
1055
1022
C
76
AUXN250
242
1802
550
530
1332
450
1105
410
1300
1267
C
87
AUXN300
287
2072
550
530
1584
450
1255
410
1552
1519
C
91
* Not always fitted refer to table above
# At 3.0 Bar
† Not to be used as the primary heat source
D
KINGSPAN ALBION
RELIABLE HOT WATER CYLINDERS