background image

BASIC ONE YEAR WARRANTY

During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials 
or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate
schedule and any repair work must be done through an authorized Kingsman dealer.

LIMITED LIFETIME WARRANTY

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted against 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor in exchange for the replacement part. Any labor, material, freight and/or handling charges associated with any repair 
or replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.

GENERAL TERMS

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit equal 
to the distributors component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 
in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being
replaced must be made available to our distributor for disposition.

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date of
manufacture plus thirty (30) days.

We will not be responsible for and you, the user, will pay for: (a) damages caused by accident, abuse, negligence, misuse, riot, fire, flood,
or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or any other 
damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or repair 
of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's components
(e) damages caused by failing to provide proper maintenance and service to the unit (f) any expenses incurred for erecting, disconnecting 
or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, inoperation or inefficiency
resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel cost whatsoever including 
additional or unusual use of supplemental electric heat.

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this unit. 
We have not made and do not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition
of fitness for a particular use or purpose. We make no express warranties except as stated in this Limited Lifetime Warranty. No one is authorized
to change this Limited Lifetime Warranty or to create for us any other obligation or liability in connections with this unit. Any implied 
warranties shall last for one year after the original installation. Some states and provinces do not allow the exclusion or limitation of incidental 
or consequential damages or do not allow limitations on how long an implied warranty or condition lasts, so the above limitations or exclu-
sions may not apply to you. The provisions of this limited warranty are in additions to and not a modification of or subtraction from any statu-
tory warranties and other rights and remedies provided by law.

Save this certificate. It gives you specific legal rights, and you may also have other rights which may vary from state to state and province to province.

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available for support
and we, in turn support the distributor's efforts.

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your files.

Model No.

Serial No.

Date installed

Dealer or Contractor Name :

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit.

LIMITED LIFETIME WARRANTY

This Limited Lifetime Warranty applies only while the unit remains at the site of the original
installation and only if the unit is installed inside the continental United States, Alaska, Hawaii,
and Canada. The warranty applies only if the unit is installed and operated in accordance 
with the printed instructions and in compliance with applicable installation and building codes 
and good trade practices.

The Ultimate in Design, Engineering & Quality

Summary of Contents for VFI30

Page 1: ...en rails mesh Removal of the smoke baffle is necessary in most cases WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of lif...

Page 2: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Page 3: ...nections 7 12 Gas Piping 8 13 Venting 8 14 Installation 10 Log Placement C5 or F5 11 Log Placement C6 12 15 Field Conversion for ZDV6000 VFI25 VFI30 13 16 Combustion Air 14 17 Unit Operation Checkout...

Page 4: ...see diagram above to secure the appliance to the floor Bedroom approved Warning Do not compromise the structural integrity of the manufactured home wall floor or ceiling during installation of applia...

Page 5: ...t light are turned off before you attempt to clean this unit 15 Clothing or other flammable material should not be placed on or near the appliance This appliance should not be used as a drying rack fo...

Page 6: ...liance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services both the appliance and the carbon monoxide detector Hav...

Page 7: ...Fan Temperature Sensor The wiring harness has two wire ends that must be attached to the Temperature Sensor The Temperature Sensor is mounted underneath the burner attached by two screws securing the...

Page 8: ...use a flame to check for leaks use an approved leak test solution 7 VENTING Before any vent liner is run through a masonry chimney or other approved venting system the chimney must be inspected clean...

Page 9: ...d in place 24 is required 6 If the lintel is wider than 12 305mm then the height of the solid fuel fireplace must be at least 28 711mm to allow for an offset elbow See Figure 2 If providing an offset...

Page 10: ...ustments 7 Slide unit into place attaching draft hood and or chimney liner as required 8 Hook up gas line 9 Hook up electrical 10 Remove glass by removing two screws behind upper grill and lifting doo...

Page 11: ...s Place log 2 on rear log holder and center it Step 3 Place Log 3 onto the notched areas as shown Place Log 4 onto the notched areas as shown Refer to step 2 for notched area locations Step 4 Place la...

Page 12: ...ocations Fill the exposed areas of the ember plates and front burner tube with ember rocks Do not place ember rocks on rear burner tube Step 4 Place lava rock around the sides and front of the burner...

Page 13: ...orward and drill out rivets Step 2 Seal rivet holes with two supplied screws ZDV6000 ONLY Step 3 Center legs of Grate Bar on either side of burner support and fasten with supplied self drilling Screws...

Page 14: ...ot be allowed to contact glass and unit should be allowed to run for a minimum of 10 minutes area of sensing tube will become quite hot A minimum draft pressure of 02 inches of water column is require...

Page 15: ...ame size is factory set The pilot flame should be at least 1 5 inches 4 cm long The flame should be impinging on the pilot generator Pilot size can be adjusted through the pilot adjust screw If the pi...

Page 16: ...blow off the soot using compressed air at high velocity It is also effective to use a clean soft brush in the area of soot accumulation Vacuuming the log with a soft brush will also work but do not f...

Page 17: ...s Replacement REPLACEMENT GLASS Only Robax ceramic or coated NeoCeram glass may be used for replacement The glass must be a minimum of 5mm thick Removal of the Glass Door 1 Remove the door by unscrewi...

Page 18: ...1001 P188SI On Off Pilot Extension Knob 5 1001 P189SI Hi Lo Extension Knob 6 2000 312 Side Louvers 7 2000 070 Fan Piezo Bracket 8 5000 P025WS Extension Spring 9 Misc 8 24 Screw 10 1000 309 Magnet 11 1...

Page 19: ...en the 4 bolts to secure all panels 3 All brass trims 4 5 and 6 are installed with 5 16 x 6 32 self tapping screws attach part 4 5 and 6 to outer edge of surround Then place On Off switch into slot up...

Page 20: ...Panel 4 2000 405 2000 424 Brass Top Trim 5 2000 405 2000 425 Brass Left Trim 6 2000 406 2000 426 Brass Right Trim 7 2000 407 2000 427 Brass Top Panel 8 2000 408 2000 428 Brass Left Panel 9 2000 409 2...

Page 21: ...SIT 820 639 and 820 640 True Millivolt Systems This System does not have a thermocouple For units with serial number greater than 13930 see 820639 820640 systems FOR SIT 820633 820634 Wiring diagram S...

Page 22: ...ated End 4 2000 085 Variable Speed Switch D 3 Twist Wire Connectors 5 1000 214 Piezo Red Button E 2 Universal Bushings 6 2000 081 Blower Motor QLN65 0024 F 1 Strain Relief Bushing 7 1000 P135WR Thermo...

Page 23: ...Trim Kit Chrome V30T2740P Trim Kit Polish Brass Size 27 3 4 High x 40 1 2 Wide V30S3044B Surround Large Kit Black V30T3044A Trim Kit Antique Brass V30T3044C Trim Kit Chrome V30T3044P Trim Kit Polish...

Page 24: ...ble Door Arch Black 355 V30ADBL Arch Door Frame Black 351 VI30RL Refractory Brick Liner 3Pce ZlMT Thermostat Millivolt Wall Mount Z80PT Thermostat Programmable Digital Millivolt Wall Mount 1F80 40 ZlR...

Page 25: ...WR Thermopile GOAI 524 1001 P069SI Electrode Sparker 915 069 TC SIT 1001 P216SI Thermocouple 290 216 TC SIT 1001 P165SI Orifice Pilot NG 977 165 TC SIT 1001 P167SI Orifice Pilot LP 977 167 TC SIT 1001...

Page 26: ...Glass Robax Neoceram 28 1 4 x 13 1 4 w Black edging 2000 092 Manual VFI30 2000 095 Thermalcord for Door 2000 BLPSI Burner Assembly Liquid Propane c w Sit Valve 2000 BNGSI Burner Assembly Natural Gas c...

Page 27: ...ot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA 16 F...

Page 28: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...