Clearances in horizontal venting.
Z58VT
-Restrictor-
Remove for Runs
Under 15 Feet
18” MIN
A)
Straight-through roof support configuration;
B)
Flex bend configuration;
C)
Termination mounting
A)
B)
C)
24”
Clearance to perpendicular wall 24 inches (60 cm). (Recommended to prevent re-
circulation of exhaust products. For additional requirements check local codes.)
Clearance above
highest point of
exit on roof 18
inches (45cm)
Shortest Vertical Run =
6-1/2ft.
Longest Vertical Run =
43ft.
2 Elbows or the equivalent
are allowed.
Maximum Horizontal Offset
= 4ft when vent run is 43ft.