Proflame 2 Module and Remote Control
Pairing Remote Control
Install the 3 AAA batteries in the battery bay, located on the
base of the Remote Control. Note polarity of the batteries
and insert them as indicated.
Connect the AC power supply to the IFC.
Press the
Remote Pairing Button
(SW1). The IFC will
“beep” and a red LED is illuminated on the Proflame 2
Module to indicate that the IFC is ready to synchronize
with a Remote Control within 10 seconds.
With the
batteries already installed in the Remote Control, push the
ON button. The receiver will “beep” four times to indicate the
Remote Control’s command is accepted.
The system is now initialized.
Resetting Proflame 2 Module for Manual Use
Should the transmitter get misplaced, broken or not wanted the
PF2 Module can be reset to a manual system. A manual on/off
switch or thermostat may be installed at the X4 connector (this
connection is Jumped at the factory) no power is required.
The following sequence must be followed to reset the PF2
Module:
Press the
SW1
button until you hear three beeps.
Within 10 seconds press the
SW1
button again until you
hear it beep.
The PF2 module may now be turned on/off manually (x4
connector) by a switch (not supplied), the pilot will remain on
CPI (continuous pilot ignition) mode, all other functions of
main burner, fan and lights will be on the high setting.
Fan Startup and Shutdown Timings:
Fan setting is started with a delay of 5 minutes from the fireplace
ignition and stopped with a delay of 12 minutes from the
fireplace switching off.
Low battery power detection
When the Remote Control’s batteries are low, a Battery Icon will
appear on the LCD display before all power is lost. When the
batteries are replaced this icon will disappear.
Battery backup
The PF2 module is powered by line voltage (AC) with provision
of battery backup in case of main power loss. Fans and lighting
features will not function with the PF2 module is powered by
battery backup. It is recommended that the 4 x AA batteries are
changed before each heating season.
REMOTE PAIRING BUTTON
(SW1 Switch)
PRESS
BUTTON
63
Summary of Contents for marquis ENCLAVE MQVL48BLPE2
Page 53: ...Gas Conversion for Modulator PART C 53...