Vent Pipe Installation IDV34 / IDV44
1. Attach the vent pipes to the termination with Millpac and 4 screws per pipe joint. Be sure to label the exhaust and
intake flex pipes. Make sure not to connect the exhaust to the intake or vice-versa. Lower the termination and vent
pipe down the vent and screw and seal plate to the chimney crown, clay tile chimney or wood stove vent. It may be
necessary to pre-drill holes into the chimney crown (depending on material) (8 screws).
2. The two vent pipes should now be hanging in the existing fireplace. Attach the adapter to the two suspended vent
pipes with Millpac and screws. Let the adapter hang in place until the unit is ready to be positioned.
3. Slide the unit into place carefully. Ensure that the adapter slides along the top of the unit, in between the guides, and
check that it remains flat. (Fig. 2)
4. Once the unit is slid back into position use the two screws previously removed to secure the adapter plate. When
tightening the adapter plate check to make sure the plate is flat to the unit and the rear catch lock is engaged over the
rear tab of unit. (Fig. 2 & 3)
5. Use Millpac to seal the vent pipe joints and ensure that it is free of any leakage.
6.
NOTE: If the factory-built fireplace has no gas access hole(s)
provided, an access hole of 1.5in [37.5mm] or less may be drilled
through the lower sides or bottom of the firebox in a proper
workmanship like manner. This access hole must be plugged with
non-combustible insulation after the gas supply line has been
installed.