IDV34 / IDV44 Glass Door Information
Glass Cleaning:
During normal startup condensation will form, causing dust and lint to cling to the surface of the glass. A
commercial fireplace glass cleaner can be used two or three times a season, depending on use of the appliance.
⚠
WARNING AND CAUTIONS
Do not clean when the glass is hot.
Do not use abrasive cleaners.
Using a substitute glass will void all product warranties.
Do not strike or abuse glass. Care must be taken to avoid
breakage of the glass.
Do not operate this fireplace without the glass front or with
a broken glass.
REPLACEMENT GLASS
Only Robax ceramic or coated NeoCeram glass may be
used for replacement. The glass must be a minimum of
5mm thick.
⚠
WARNING:
No substitute materials may be used other than factory
supplied components.
Spring Replacement:
Over time the spring may need to be replaced if tension is lost. Replace spring as follows:
1. Remove the top latches by unfastening the two [2] hex screws that secures it in place. They are located in the firebox.
2. Remove the bottom latches by unfastening the four [4] hex screws located in the firebox (beside the burner assembly).
Once the screws are all removed, the latches will either fall or slide out.
3. To remove the spring, unfasten the one [1] lock nut holding it in place. NOTE: When replacing a spring tighten the lock
nut so that the total compression length is 3-1/2". This is critical for proper tension
.
IDV34 / IDV44 Glass Door Removal and Installation
1. Disengage Top Latches by pulling on Latch Pull with one hand and
pushing up on Latch Pull with the thumb of your other hand (See Photos
to left).
2. Once the top of the door is unlatched, pull it outwards and up to unlatch
the bottom.
3. To re-install, place the Bottom Door Ledge into the Lower Latch assembly
first. Then swing the door closed to seal it against the firebox cavity.
4. To re-latch the Upper Latch assembly, Pull on Latch Pull with one hand
and push up with other hand. Lift Latch over Door Hook and allow Latch
Hook to drop down over the Door Hook.
Latch Pull
To Disengage Top Latch:
TO REPLACE GLASS:
Clean all materials from door frame. Using a high heat silicone (resistant
to 500°F [260°C]) apply a bead of approximately 1/8” to all four sides of
frame and insert glass with new gasket. The door frame should be on a
flat surface with a small amount of weight pressing the glass into the
silicone. Let everything dry for approximately 15 to 20 minutes.