AIR FOR COMBUSTION AND VENTILATION Cont.
VENTILATION AIR FROM INSIDE BUILDING
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space,
you must provide two permanent openings: one within 12” of the ceiling and one within 12” of the floor on the wall
connecting the two spaces (see options 1 and 2, Figure 4).
You can also remove door into adjoining room (see option
3, Figure 4). Follow the
National Fuel Gas Code NFPA
54/ANSI Z223.1, Section 5.3, Air for Combustion and
Ventilation
for required size of ventilation grills or ducts.
FIGURE 4 - Ventilation Air from Inside Building
WARNING
Rework worksheet, adding the space of the adjoining
unconfined space. The combined spaces must have
enough fresh air to supply all appliances in both spaces.