IDV24
Chimney Cavity Insulation
If You Live In A Cold Climate Zone And Your Chimney Is On The Side Of Your House
In cold climates, especially where the chimney is located on the outside of the home it may be necessary to insulate the
chimney cavity with NON-COMBUSTIBLE insulation such as vermiculite or Roxul insulation. This will keep the chimney
cavity warm and avoid cold start ignition problems.
FOLLOW ALL LOCAL CODES.
-Vertical Venting Runs Taller Than 15 Feet-
We recommend that the pilot be left on at all times for vertical venting runs taller than 15 feet. This will maintain a
slight draft in the vent, allowing the burner to light quickly.
The pilot should be lit ½ hour before turning on appliance. The pilot should be left on during the heating season.
IDVLCP
(Seal this plate with
RTV Red Silicone.)
NON-COMBUSTIBLE
INSULATION
(Vermiculite, Roxul, etc.)
53