IDV24
-Gas Conversion Part A-
IDV24N, IDV24NE, IDV24NE2, IDV24LP, IDV24LPE, IDV24LPE2
Kit Number
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass Nipple
Air Shutter
Hi/Lo Regulator
24IDV-CKLP
Propane Conversion
-Millivolt-
1001-P167SI
#30
(977.167)
#52
1000-P201VE
Hex
Fully Open
1001-P202SI
(0.907.202)
24IDV -CKNG
NG Conversion
-Millivolt-
1001-P165SI
#51
(977.165)
#41
1000-253 Close
1/8
”
1001-P201SI
(0.907.201)
24IDV-CKLPI
Propane Conversion
-IPI-
1001-P168SI
#35
(977.168)
#52
1000-P201VE
Hex
Fully Open
1002-P014SI
(0.907.014)
24IDV-CKNGI
NG Conversion
-IPI-
1001-P166SI
#62
(977.166)
#41
1000-253 Close
1/8
”
1002-P016SI
(0.907.016)
24IDV-CKLP2
Propane Conversion
-IPI-
1001-P168SI
#35
(977.168)
#52
1000-P201VE
Hex
Fully Open
1002-P012SI
(907.012)
24IDV-CKNG2
NG Conversion
-IPI-
1001-P166SI
#62
(977.166)
#41
1000-253 Close
1/8
”
1002-P013SI
(907.013)
IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK TESTING.
⚠
Caution
:
The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
1. The Burner Tube must be removed from the Burner Pan Assembly (See
Burner Tube Removal
). Adjust the Air Shutter to the correct Primary Air
setting as specified in the manual or on the label plate. To adjust the
Primary Air setting, loosen screw on the side of the Air Shutter and rotate to
the correct opening using a drill bit or tape measure. Retighten screw.
2.
Remove the Main Orifice using a ½” wrench and replace with the new
Conversion Orifice which came with the Conversion Kit.
3.
Replace the Burner Tube. Install the new Pilot Orifice (See
Pilot
Conversion
) and Hi/Lo valve regulator by following instructions supplied
with the Conversion Kit.
•
Refer to
Gas Specifications Chart
for inlet pressures and input
ratings.
•
Clock meter to verify input rate.
•
Place conversion label as close to converted gas control as
possible.
•
Refer to
lighting instructions
to verify the normal operating
sequence of the ignition system.
•
Refer to
Burner System Maintenance
for proper relationship of
the pilot flame to the main burner and for main burner flame
appearance.
-
⚠
Warning-
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having
jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this kit. The installation is
not proper and complete until the operation of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit.
Parts List (SIT):
•
HI/LO Pressure Regulator
Assembly
•
Burner Orifice
•
Brass Nipple
•
Instructions
•
Conversion Kit Label
•
Pilot Orifice
Air Shutter Adjustment can be made by
removing right side Ember Plate.
Ember Plate
(Right Side)
Burner System shown removed for clarity only.
29