SOLACE/SKYLINE 

Installation Instructions

 

 MQHBZDV3636, MQHBZDV4236, MQRB4236T, HBZDV4736 

Models:

MQHBZDV3636N, MQHBZDV3636NE, MQHBZDV3636NE2, MQHBZDV3636LP, MQHBZDV3636LPE,            

MQHBZDV3636LPE2 

Models:

 MQHBZDV4236N, MQHBZDV4236NE, MQHBZDV4236NE2, MQHBZDV4236LP, MQHBZDV4236LPE, 

MQHBZDV4236LPE2 

Models:

MQRB4236NT, MQRB4236NTE, MQRB4236NTE2, MQRB4236LPT, MQRB4236LPTE, MQRB4236LPTE2 

Models:

 HBZDV4736N, HBZDV4736NE, HBZDV4736NE2, HBZDV4736LP, HBZDV4736LPE, HBZDV4736LPE2 

Certified to:

 ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters, CSA 2.17-2017 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A Division of R-Co. Inc. 

2340 Logan Avenue 

Winnipeg, Manitoba, Canada R2R 2V3 

Ph: (204) 632-1962 

Printed in Canada February 9, 2021 

Part # 36MQ-MAN17 

INSTALLER: Leave this manual with the appliance. 

 

CONSUMER: Retain this manual for future reference. 

For Propane Horizontal installations the venting 

must be a minimum of one foot vertical off the 

flue before going horizontal. 

This appliance may be installed in an aftermarket, 

permanently located, manufactured home (USA 

only) or mobile home, where not prohibited by 

local codes. 

This appliance is only for use with the type of 

gas indicated on the rating plate. This appliance 

is not convertible for use with other gases, 

unless a certified kit is used.

 

VENTED GAS FIREPLACE HEATER: 

NOT FOR USE WITH SOLID FUEL. 

Summary of Contents for HBZDV4736

Page 1: ...sion of R Co Inc 2340 Logan Avenue Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada February 9 2021 Part 36MQ MAN17 INSTALLER Leave this manual with the appliance CONSUMER Retain thi...

Page 2: ...sman Fireplace Venting Parts 27 COMMON SECTION Clearances Mantels 28 Mantel Leg Clearances 29 Fan Installation 30 Split Receptacle Fan Speed Control Outside of Fireplace 31 Installing MQRB4236T Liner...

Page 3: ...ame Control Room Thermostat 67 Smart Thermostat Fan Speed Control Light Control 68 Label Schematic 69 VENTING SECTION Vent Terminal Clearances 70 General Vent Installation Information 71 Installation...

Page 4: ...sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be...

Page 5: ...until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper cli...

Page 6: ...SI Z21 88 IN THIS MANUAL MAY BE INSTALLED IN MANUFACTURED MOBILE HOMES IN CANADA Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electric...

Page 7: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...

Page 8: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Page 9: ...mal shock Take care to prevent water from contacting the fireplace especially if it is hot See Through Units are suitable for an outdoor location but not on the outside wall of a house or other struct...

Page 10: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Page 11: ...e the elbow on any horizontal runs of one foot or greater This allows for cleaner combustion and greatly reduces carboning and cleaning of glass MQHBZDV3636 Framing for your Gas Fireplace MQHBZDV36 Lo...

Page 12: ...HBZDV36 WITH HB36CVCK CLEAN VIEW CIRCULATING KIT HBZDV36 Framing and Facing Requirements Non Combustible Header Attached AA Non Combustible Header Attached AA AA AA AA 12...

Page 13: ...fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum Enclosure of 42 to 43 inches 3 1 2 inches 89 mm All Vent Systems Top of 90 degree bend in Enclosure over 43...

Page 14: ...T 1001 P165SI Orifice Pilot NG 977 165 TC SIT 1001 P167SI Orifice Pilot LP 977 167 TC SIT 1001 P633SI Valve Nova LP Hi Lo 0820651 1001 P634SI Valve Nova NG Hi Lo 0820652 1001 P713SI Pilot Burner LP 19...

Page 15: ...hield Large Return Z47GP36 Galvanized Pipe 7 Dia x 36 Vertical Installations ZDVAAF Flashing 7 c w Storm Collar 1 12 to 7 12 ZDVAF2 Flashing 7 c w Storm Collar 8 12 to 12 12 ZDVAF3 Flashing 7 c w Stor...

Page 16: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Page 17: ...of two and a half 2 5 inches above the bend in enclosures 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB42CVCK Clean view Circu...

Page 18: ...HBZDV42 WITH HB42CVCK CLEAN VIEW CIRCULATING KIT HB42 Framing and Facing Requirements Non Combustible Header Attached Non Combustible Header Attached 18...

Page 19: ...om of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum Enclosure of 45 to 46 inches 5 inches 128 mm All Vent Systems Top of 90 degree bend in Enclosure over...

Page 20: ...sembly Natural Gas c w Valve System MQRB4236NT 4236RBT BLPSI Burner Assembly Liquid Propane c w Valve System MQRB4236LPT Conversion Kit Sit Valve Only 4232HB CKLP MQHBZDV4236LP Millivolt 4232HB CKLPI...

Page 21: ...Termination converts from 15 40 to under 15 FDVHT Horizontal Vent Termination FDVHSQ Horizontal Square Termination Z47ST24 Horizontal Snorkel Termination 24 Z47ST36 Horizontal Snorkel Termination 36...

Page 22: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Page 23: ...nsulation sleeve is not required 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB47CVCK Clean view Circulating Kit floor or hearth...

Page 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...

Page 25: ...p of 90 degree bend in Minimum with insulation sleeve Enclosure of 50 1 2 to 56 1 2 inches 2 1 2 inches 64 mm All Vent Systems Top of 90 degree bend in without insulation sleeve Enclosure over 56 1 2...

Page 26: ...1001 P633SI Valve Nova LP Hi Lo 0820651 1001 P634SI Valve Nova NG Hi Lo 0820652 1001 P713SI Pilot Burner LP 199 713 TC SIT 1001 P714SI Pilot Burner NG 199 714 TC SIT Optional Thermostats and Remote C...

Page 27: ...hield Large Return Z47GP36 Galvanized Pipe 7 Dia x 36 Vertical Installations ZDVAAF Flashing 7 c w Storm Collar 1 12 to 7 12 ZDVAF2 Flashing 7 c w Storm Collar 8 12 to 12 12 ZDVAF3 Flashing 7 c w Stor...

Page 28: ...s HB36 HB42 HB47 Mantels Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combustible...

Page 29: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Page 30: ...set screw on the side of vari able speed controller to increase or decrease the minimum fan speed lowering minimum fan speed will decrease sound level created by fan Reinstall switch into wall mount a...

Page 31: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Page 32: ...Remove 2 DT Screws from Firebox sides Do not discard these screws Place Side Panels into Firebox as shown in Ref 3 below tilt and slide into place Replace and tighten DT Screw through hole in top of S...

Page 33: ...ce optional front bridge ledge 3 in the area front of false bottom 5 Place rear Brick Panel 4 up against the rear of Firebox by tilting top of panel towards you and sliding bot tom of Panel over the b...

Page 34: ...k Clip out of the way and slide Side Panel up against Back Panel Side Panel tabs should engage top and bottom of Back Panel See Ref 3 Rotate Brick Clip down over Side Panel and tighten screw 5 Re inst...

Page 35: ...ng its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 KPa Note The gas line connection may be made of 1 2 rig...

Page 36: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Page 37: ...as valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifi...

Page 38: ...ing Burner System 1 Disconnect gas line connection at burner system through access cover opening CAUTION ALL WORK SHOULD BE PERFORMED BY A QUALI FIED AND CERTIFIED TECHNICIAN 2 Remove extension knobs...

Page 39: ...intermittent or standing pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly F...

Page 40: ...ition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure res...

Page 41: ...66 36 1000 P201VE Hex 3 16 1002 P013SI 907 013 4236RBT CKLP MQRB4236LPT Propane Conversion Millivolt 1001 P167SI 30 977 167 53 1000 P201VE Hex 1 4 1001 P201SI 0 907 201 4236RBT CKLPI MQRB4236LPTE Prop...

Page 42: ...he correct setting as specified in the manual or label plate To adjust air setting loosen screw on the side of air mixing tube and rotate to the correct opening using a drill bit or tape measure Retig...

Page 43: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Page 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...

Page 45: ...heat silicone tempera ture resistant to 500 F 260 C apply a con tinuous bead of approximately 1 32 to all four sides of frame and insert glass with new gas ket Frame should be on flat surface with a...

Page 46: ...tom of logs 4 and 5 Position them onto left and right log placement tabs STEP 4 Locate the hole on the bottom of log 6 Place onto the mounting tab on log 2 Locate the 2 holes on the bottom of log 7 Pl...

Page 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...

Page 48: ...orts and the grate bar STEP 2 Attach the back rock support with the 4 screws as shown Replace reinstall the 2 screws from the grate bar STEP 3 Using the platform mount access holes attach the rock pla...

Page 49: ...STEP 7 Place rocks 4 onto the burner as shown STEP 8 Place rocks 6 onto the burner as shown STEP 9 Place remaining rocks 4 and 6 into position as shown Finished Rock F2 Setup Placement of rocks for s...

Page 50: ...tall the 2 screws from the grate bar STEP 2 Attach the back rock support using the existing screws from the back log holder Using the platform mount access holes attach the rock platform as shown STEP...

Page 51: ...shown Do not place rocks directly onto the burner tubes STEP 6 Place rocks 4 into position as shown STEP 7 Place rocks 6 into position as shown STEP 8 Place remaining rocks 4 and 6 into position as sh...

Page 52: ...nition can occur The following types of glass are approved Ember Glass Material from American Fireglass Maximum amount Natural Gas is 5 lbs Propane units 5 lbs Liquid Glass from Firegear Maximum amoun...

Page 53: ...KIT Optional Accent Lighting Kit See separate installation page NOTE Glass Media must be evenly spread over the Burner and False Bottom as described on last page before Rock Stones and Log Accessorie...

Page 54: ...t lamp wires through access hole in firebox as above Apply new sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22...

Page 55: ...facing upward or sideways Replace burner tube and false bottom along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to trans...

Page 56: ...ppliance is still operable NOTE In certain instances the IPI Main Module requires resetting This can occur if the system is unable to ignite the pilot or the main burner in the allotted time period Th...

Page 57: ...splay on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set...

Page 58: ...P 977 168 35 IPI 11 1002 P012SI IPI Stepper Kit LP 907 012 12 1002 P013SI IPI Stepper Kit NG 907 013 13 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 14 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 15 1002 P01...

Page 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...

Page 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...

Page 61: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Page 62: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 62...

Page 63: ...clockwise to off Located behind the access panel 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above...

Page 64: ...IPI Assembled NG 199 033 14 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 15 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 16 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 17 1001 P280SI TC T...

Page 65: ...must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 Module may now be turned on off...

Page 66: ...ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Dis...

Page 67: ...Proflame 2 Remote Control 67...

Page 68: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 68...

Page 69: ...69...

Page 70: ...3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m Notes 2 M Clearance under veranda porch deck or balcony 12 in 30 cm 12 in 30 cm N Where a ve...

Page 71: ...ends place spring in bend or before and after See Fig 1 Horizontal runs require support metal straps every 2 feet In offset installation support straps should be used to stabilize pipe Expand 4 and 7...

Page 72: ...the 4 flex pipe as required Then attach the seven inch 7 pipe by the same method 8 Support horizontal pipes every two 2 feet 61 cm with metal strap bands Re check fireplace to make sure it is levelle...

Page 73: ...and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use...

Page 74: ...w well is recommended with adequate and proper drainage as per local codes Leave 2 clearance below snorkel to prevent water from entering the Snorkel Termination Do not enclose the Snorkel within a wa...

Page 75: ...rulers or by using a roof pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the sh...

Page 76: ...upport configuration B Flex bend configuration C Termination mounting Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requireme...

Page 77: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Page 78: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Page 79: ...not supplied to connect to the Power Vent Termination SECTION 2 FLEX VENT Used for entire installation order Z47PVA Note Must use a one foot section of 5 8 DV hard pipe connected to the power vent on...

Page 80: ...OWER VENT ACCESSORIES ZDV4FC Flex Connector 4 Diameter ZDV7FC Flex Connector 7 Diameter ZDV4FCL Flex Clamp 4 ZDV7FCL Flex Clamp 7 ZDV4SS Spring 4 Standoff Spacer PVH58WT Wall Thimble for Power Vent 80...

Page 81: ...hemicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matchi...

Reviews: