6
OIL WARNING SYSTEM
When the oil level falls below the lower level, the engine
stops automatically. Unless you refill with oil, the engine
will not start again.
ECONOMY CONTROL SWITCH
When the economy control switch is turned
ON
, the
economy control unit will change the engine speed
according to the connected load. The results are improved
fuel economy and less noise.
ENGINE AND FUEL COCK SWITCH
The engine switch controls the ignition system.
①
ON (RUN)
Ignition circuit is switched on. The engine can be started.
②
OFF (STOP)
Ignition circuit is switched off. The engine will not run.
CIRCUIT BREAKER
The circuit breaker switch controls the AC output.
①
ON
AC output is on.
②
OFF
AC output is off.
OUTPUT RESET
Push the reset button continuously for 2 seconds, this will
reset the AC output if the generator has stopped due to
the overload protection.
NOTE
If the overload protection has been tripped ensure the total
load does not exceed the rated power output.