background image

-7-

Thank you for choose KINGREX SLAP. It provides you with better protection for connected equipment. 

We sincerely hope you could keep the user manual for whole SLAP life.

    Please read this user manual very carefully. It provides safety, installation, and operating instructions   

    that will help you derive the over all performance and fully extend the life that the SLAP has to offer.     

     Please save this manual! It includes important instructions for the safely use SLAP and for obtaining 

    factory service should the proper operation of the SLAP come into question. 

    Please save or recycle the packaging materials! The SLAP’s shipping materials were designing with  

    great care to provide protection from transportation related damage. These materials are invaluable if 

    you ever have to return the SLAP for service. Damage sustained during transit is not covered under 

    the warranty.

To reduce the risk of electric shock, disconnect the SLAP from the mains supply before installing an 

amplifier . Reconnect the power cord only after signaling interconnections have been made. 

    1.  Do not dispose of batteries in a fire, the battery may explore. 

    2.  Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes.

A battery can present a risk of electric shock and high short circuit current. The following precaution 

should be observed when working on batteries 

    1.  Remove watches, rings or other metal objects. 

    2.  Use tools with insulated handles. 

-   

Caution

: Risk of electric shock - hazardous live parts inside this unit are energized from the     

                    battery supply even when the input AC power is connected. 

-   

Caution

: Risk of electric shock, do not remove cover. No user serviceable parts inside, Refer 

                    servicing to qualified service personnel. 

-   

Warning

: To reduce the risk of fire, replace only with the same type and rating of fuse. 

-   

Warning

: To reduce the risk of fire or electric shock, install in temperature and humidity controlled 

                     indoor area of conductive contaminants.   

Important safety instructions 

   

Safety caution! 

Summary of Contents for SLAP

Page 1: ...SLAP USER MANUAL SLAP USER MANUAL...

Page 2: ...If the PSU OFF the charging process is still working but it can not be show the monitoring status through the LED as it won t light A Content B Introduction C Specification D Design Consideration of...

Page 3: ...50mA Stage 2 current 400mA Stage 3 float charge current 200 400mA Charging current Charged light turns on and float charge starts when the charge current is approx 80mA when the battery charge voltage...

Page 4: ...ration If the demands of the amplifier exceed the capabilities of the power of the power supply during transient conditions deep bass passages then detail loss smearing and distortion can occur The th...

Page 5: ...table and will not deteriorate When the output power is relatively high more DC current will be drawn from the capacitors putting a strain on the rectifier diodes and causing AC ripple voltage When a...

Page 6: ...ply unit will be the best solution for fully isolated power source from AC environment as the internal AC power is only used for charging The AC power source will be totally isolated one switching but...

Page 7: ...US firm The maximum current capability is 6 amps 5 AC input fuse and DC output fuse for safety consideration 6 Battery Low Voltage monitoring circuit to ensure extended automatically shuts the system...

Page 8: ...shock disconnect the SLAP from the mains supply before installing an amplifier Reconnect the power cord only after signaling interconnections have been made 1 Do not dispose of batteries in a fire th...

Page 9: ...ecrease the charging current from 200 400mA into 80mA maintain charge b Green Charging completed and still keeping maintain charge 80mA Advantage Battery charging should be high current while it began...

Page 10: ...BLE SLAP TO CHARGE MODE PSU ON SWITCH ENABLE SALP DC OUTPUT ON AC FUSE SLOT 2A 250V FUSE FUSE FOR DC OUTPUT 3A 250V DC OUTPUT BATTERY DC POWER OUTPUT PSU ON CHARGER ON DC OUT OFF PSU ON CHARGER OFF DC...

Page 11: ...erate the SLAP where the temperature and humidity is outside the specified limits Charge the battery The SLAP charges its battery when CHARGER ON SWITCH IS ON charge the battery for 24 hours in the in...

Page 12: ...and hex screw driver to open the front panel upside screw 3 Using a phillips screw driver to unlock the main circuit board 4 Carefully lift off main circuit board using a phillips screw driver to unl...

Page 13: ...ry 6 months During extended storage in environments where the ambient temperature is 30 to 45 86 to 113 charge the SLAP s battery every 3 months Trouble Shooting PROBLEM POSSIBLE CAUSE ACTION TO TAKE...

Page 14: ...welcome to contact KingRex Technology Co LTD directly if you need any information or help Our contact information is listed on the last page of this user guide Our best wishes We only use the best raw...

Page 15: ...e change for service components The warranty is annulment by following condition The damage of machine by artificial damage improper using repair or refit by yourself nature disaster lightening strike...

Page 16: ......

Reviews: