AC/DC Fridge
An AC/DC fridge option is provided with the Dockside
package Both AC and DC power can be connected
to the fridge at the same time The unit will always run
on AC when AC power is available. Should the AC be
disconnected there is a one minute time delay before the
unit continues to run on DC If AC power is reintroduced
the unit immediately switches back to AC
Start up: Turn the power on and set the thermostat
between 3 and 4 You can make further adjustments after
the box has cooled down Allow the refrigerator to come
down to temperature before putting product in Setting
the thermostat to a higher setting i e 7, will not decrease
the time required for the unit to cool down to its normal
operating temperature AC/DC units cool at the same rate
on DC as on AC
Two Burner Alcohol Stove
The ORIGO stove has a non-pressurized alcohol burner.
The alcohol is absorbed into a non-flammable material
in the canister. Remove the cutting board. Pull the stove
top latch forward and lift the stovetop up. Caution should
be taken while fueling the canister. Be sure the flame is
completely extinguished. Remove each canister from the
stove to fuel one at a time. It should be cool enough to
be tangible with bare hands. Do not over fill the canister.
Max capacity is 1 quart. Check the fuel level by tilting the
canister vertically. Hold this position for 5-10 seconds.
Once the fuel is visible in the non-flammable material at
the bottom of the opening, the canister is full. The stove
will operate if the canister is not filled to the max capacity.
Be sure to clean up any spilt fuel. Close the stove top
before lighting
Lighting the burner: A hand held butane bbq lighter is
recommended Slide the control to the maximum opening
Stick the lighter in towards the canister and ignite
Extinguishing the flame: Slide the control to the “Off”
position. Wait a few moments. Confirm the flame is
extinguished by opening it back to wide open Repeat if
flame is still burning. Wait until the stovetop is completely
cooled off before replacing the cutting board
MODEL
STATION
OPERATION
(Please refer to the drawing at bottom of page)
1. Turn main breakers off
2. Remove shorepower cord from boat outlet if present
6. If the multimeter display counts from zero to 1 volt (1000mV) the galvanic isolator is connected properly.
All models with invertors
QC
Galvanic isolator and hull bond testing
3. Discharge the galvanic isolator by touching a wire to the ground connection of the shore power plug (G) and to a chassis ground source (exposed metal or screw
fastener that is fastened though metal).
4. Set multimeter to the diode check setting (symbol #14 on a meter).
5. Connect the multimeter RED lead to the ground connection of the shore power plug (G) and the BLACK lead to a chassis ground source (exposed metal or screw
fastener that is fastened though metal).
7. Repeat steps 3-6, but alternate RED lead to chassis and BLACK lead to the shore power receptacle ground. Conducting this second test will ensure that the galvanic
isolator is WORKING properly.
02/09/2018
Galvanic Isolator
Every boat that receives a shore power package also receives a galvanic isolator. The isolator works by interrupting
galvanic circuits created with other boats and the dock when the boat shore power is plugged in and operational.
The galvanic isolator’s operational indication lights are visible behind the helm seat through an access hole in the
carpeted shore power panel mounting board
30 KINGFISHER BOATS 3125
|