7
Electromagnetic / Compatibility:
Vac and Aac only: RF field = 3V/m
Total accuracy = specified a2.0% of range
Safety:
600V CAT II Regulation EN61010; Part 1: 1993
Cerification:
Continuity Beeper
Range
Active Range
Test Voltage
Overload protection
under40
Ω
<1.5V
600Vrms
DC Voltage ( Auto Range)
Range Resolution Accuracy Input Impedance Overload Protection
400mV
0.1mV
0.5%+2
>1000 M
Ω
750V rms
750V rms
750V rms
750V rms
750V rms
4V 1mV
0.5%+2
11M
Ω
40V 10mV
0.5%+2
10M
Ω
400V
100mV
0.5%+2
10M
Ω
600V
1V
0.8%+2
10M
Ω
1-2
Electrical Specifications
Accurace specification:
±([… %of r […number of least significant
digits]) at 18°C to 28°C ( 64°F to 82°F ) 80%RH
Diode Tester
Range Resolution Accuracy Test Current Test Voltage Overload
protection
1mV
1%+ 2
<1mA
<3.2V
600Vrms
Summary of Contents for 9DM1371
Page 1: ...customer service e mail service clients kingtony eu Notice Instruction MULTIMETRE DIGITAL ...
Page 2: ......
Page 4: ......
Page 29: ......
Page 31: ......
Page 55: ...customer service e mail service clients kingtony eu Manual de instrucciones POLÍMETRO DIGITAL ...
Page 56: ......
Page 58: ......