background image

1

Read First: SafetyInformation

Never use the meter if the meter or test 

leads look damaged.

Be sure the test leads and switch are in the 

correct position for the desired measurement.

Never measure resistance or testing acoustic 

continuity in a circuit when power is applied.

Never connect the probe to a voltage source 

when the test leads are plugged into the 10 A 

input jack .

Never connect the probe to a voltage source 

when the function are in uA or mA range.

Never apply more than rated voltage between 

any input jack and earth ground.

Be careful when working with voltages above 

60 V dc or 30 V ac rms. Such voltages pose a 

shock hazard.

Summary of Contents for 9DM1371

Page 1: ...customer service e mail service clients kingtony eu Notice Instruction MULTIMETRE DIGITAL ...

Page 2: ......

Page 3: ...hoix de mesure 2 2 2 Mesure de tension DC 2 2 3 Mesure de tension AC 2 2 4 Mesure d intensité AC DC 2 2 5 Vérification de diode 2 2 6 Mesure de résistance 2 2 7 Mesure de courant continu 2 2 8 Mesure de fréquence 3 Remplacement des piles et fusibles 3 1 Vérification et remplacement des piles 3 2 Remplacement des fusibles 4 Maintenance 1 3 3 7 10 10 14 14 14 15 16 17 18 19 20 21 21 22 23 MENU MENU ...

Page 4: ......

Page 5: ...ce et ne testez jamais la continuité acoustique sur un circuit sous tension Ne jamais connecter la sonde à une source de tension quand les fils test sont reliés à la prise 10A Ne jamais connecter la sonde à une source quand la fonction est sur uA ou mA Ne jamais appliquer plus que la tension évaluée entre une prise et le sol Faîtes attention quand vous travaillez avec des tensions supérieures à 60...

Page 6: ...vaises lectures remplacez les piles dès qu l icône apparaît Lire d abord les précautions d emploi Tension dangereuse peut être présente Le multimètre est protégé par une double isolation ou par une isolation renforcée Comply with IEC1010 1 CAT II Quand vous réparez l appareil n utilisez que des pièces de rechanges agrées ...

Page 7: ... 2 000m d altitude Utilisation en intérieure uniquement Taux d humidité 80 max Température ambiante 0 40 C Entretien et nettoyage Les réparations et entretiens non traités dans ce manuel doivent être effectuées par une personne compétente Nettoyer régulièrement l appareil avec un tissu propre et du détergent Ne jamais utiliser de produits abrasifs ou de solvants sur les éléments ...

Page 8: ...ise de données Sonnerie continue Diode AC Symbole Mode manuel Indications en barres DC Symbole Batterie faible Mode automatique Lecture relative Prise de données Valeur maximum Valeur minimum Sonnerie continue Diode Courant alternatif ou tension Courant continu ou tension ...

Page 9: ... négative Mode manuel Indications en barres Fréquence Tension Milvolt 1 X 10 volt Ampère amps Microampère 1 X10 6 amp Milliampère 1X10 3 amp Ohm Résistance Kilohm 1 X 103 ohm Résistance Megohm 1X106 ohm Résistance ...

Page 10: ... type AAA Durée de vie des piles 500 heures environ alcalines Polarité indique la polarité négative Mise en arrêt automatique au bout de 30 minutes Température et humidité de fonctionnement 0 C à 40 C 32 F à 104 F au dessous de 80 RH Température et humidité de rangement 10 C à 60 C 14 F à 140 F au dessous de 70 RH Temperature Coefficient 0 1 x Specified accuracy C 18 C or 28 C Poids environ 220g D...

Page 11: ...ms Tension DC mode auto Plage Résolution Précision Entrée impédance Protection 400mV 0 1mV 0 5 2 1000MΩ 750V rms 750V rms 750V rms 750V rms 750V rms 4V 1mV 0 5 2 11MΩ 40V 10mV 0 5 2 10MΩ 400V 100mV 0 5 2 10MΩ 600V 1V 0 8 2 10MΩ 1 2 Spécifications électriques Spécification d exactitude de la mesure nombre affiché sur l écran de 18 C à 28 C et en dessous de 80 RH Test de diode Plage Résolution Préci...

Page 12: ...z 1KHz Protection 400uA 0 1uA 1 3 5 1 6 5 0 25Vrms 0 5A 250V Fusible rapide 4000uA 1uA 1 3 5 1 6 5 1Vrms 0 5A 250V Fusible rapide 40mA 10uA 1 3 5 1 6 5 0 25Vrms 0 5A 250V Fusible rapide 400mA 100uA 1 3 5 1 6 5 1 5Vrms 0 5A 250V Fusible rapide 10A 10mA 1 5 5 1 8 5 0 35Vrms 10A 250V Fusible rapide Précision Plage Résolution 45Hz 400Hz 400Hz 1KHz Entrée impédance Protection 400mV 0 1mV 1 5 45Hz 100Hz...

Page 13: ... 2 1 5VDC 600Vrms 400KΩ 100Ω 0 75 2 1 5VDC 600Vrms 4MΩ 1KΩ 0 75 2 1 5VDC 600Vrms 40MΩ 10KΩ 1 2 3 1 5VDC 600Vrms Plage Résolution Précision Sensibilité Protection 4 KHz 1Hz 0 1 1 300mVpp 600V rms 40KHz 10Hz 0 1 1 300mVpp 600V rms 400KHz 100Hz 0 1 1 300mVpp 600V rms 4MHz 1KHz 0 1 1 3Vpp 600V rms 40MHZ 10KHz 0 1 1 3Vpp 600V rms Fréquence mode auto ...

Page 14: ... Hz mA A IEC 1010 POLLUTION DEGREE 2 F 0 5A 250V F 10A 250V WARNING 600V CAT II 2 Eléments et commandes 2 1 Nom des pièces et position Affichage LCD Sont affichés les valeurs mesurées unités fonctions et symboles 1 2 3 6 7 8 4 5 9 ...

Page 15: ...rtir du mode relatif Bouton mode auto mode manuel Appuyer sur le bouton pour sélectionner le mode manuel l icône s affichera et le multimètre restera sur le même mode qu il était Dans le mode manuel chaque fois que vous appuyez sur le bouton la plage augmente et une nouvelle valeur s affiche Si le multimètre est sur la plage la plus grande la prochaine plage sera la plus petite Pour sortir du mode...

Page 16: ...ncore dessus pour sélectionner la valeur MIN et encore une fois pour valider la valeur l icône clignote Rester appuyer pendant 1 seconde pour sortir du mode Bouton AC DC et Ω Select Button Pour sélectionner la fonction AC ou DC dans la plage d ampère Pour sélectionner la mesure continue ou la mesure de résistance du mode Fonction sélecteur de commutateur Pour éteindre et sélectionner la plage de f...

Page 17: ... fil test rouge et mesurer le courant jusqu à 10A Connecteur de mesure VΩ μA mA Hz Pour connecter le fil positif fil test rouge et pour la mesure de tension de diode de fréquence de microampère de milliampère et de continuité Note Afin d éviter de griller un fusible utiliser la sortie 10A quand vous êtes sûre que le courant est en dessus de 400mA quand vous mesurez du courant continu Support d inc...

Page 18: ... 2 2 2 Mesure de tension DC ATTENTION La tension d entrée maximale est de 600V AC DC N essayez pas de prendre la mesure d une tension qui pourrait l excéder afin d éviter les risques d électrocution et ou le dommage de l appareil Connecter le fil test rouge à la prise V et le fil test noir à la prise COM Positionner le bouton central sur mode V Connecter les fils test en parallèle au circuit qui d...

Page 19: ...sur mode V Connecter les fils test en parallèle au circuit qui doit être mesuré Relever la valeur de la tension qui s affiche sur l écran La tension d entrée maximale est de 600V AC DC N essayez pas de prendre la mesure d une tension qui pourrait l excéder afin d éviter les risques d électrocution et ou le dommage de l appareil 1 2 3 4 ...

Page 20: ...ral sur le mode A et appuyer sur le bouton DC AC pour choisir la fonction AC DC Couper le courant sur le circuit à tester et connecter l appareil EN SERIE sur le circuit avec le fil test noir sur le pole négatif et le fil test rouge sur le pole positif a mesurer Appliquer le courant et lire la valeur sur l écran Pour éviter les dommages n essayez pas de mesurer du courant si le circuit ouvert à un...

Page 21: ...e et le fil test noir du coté cathode de la diode à tester Lire la valeur de la tension V sur l écran la polarité des fils test est inversée avec la polarité de la diode l écran affichera OL Il ne peut pas distinguer le terminal anode et cathode d une diode Avant de prendre la mesure sur un circuit enlever le courant du circuit a tester et décharger tous les condensateurs sur le circuit 1 2 3 4 5 ...

Page 22: ...OM Positionner le bouton central sur le mode Ω et appuyer sur le bouton pour la fonction Ω Connecter le fil test au circuit à mesurer et lire la valeur de résistance sur l écran Avant de prendre la mesure sur un circuit enlever le courant du circuit a tester et décharger tous les condensateurs sur le circuit 1 2 3 ...

Page 23: ...ger tous les condensateurs Connecter les fils test au circuit à mesurer Quand l impédance entre les prises test est inférieure à 40Ω il peut activer une sonnerie continue 2Khz Note Le test de continuité permet de savoir si le circuit est ouvert ou court circuité Avant de prendre la mesure sur un circuit enlever le courant du circuit a tester et décharger tous les condensateurs sur le circuit Circu...

Page 24: ...necter le fil test rouge à la prise Hz et le fil test noir à la prise COM Sélectionner le mode Hz avec le bouton central Connecter les fils test en parallèle sur le circuit à mesurer Lire la valeur de la fréquence sur l écran 1 2 3 4 ...

Page 25: ...r 2 piles type AAA de 1 5V 2 le bouton central sur OFF Utiliser un tournevis pour ôter la coque arrière Enlever les piles usées et les remplacer par des piles neuves de type AAA 1 5V 3 Replacer la coque arrière et fermer avec les même vis qui étaient en place Afin d éviter une électrocution mettre le multimètre sur OFF et déconnecter les fils test avant d enlever la coque arrière ...

Page 26: ...eux et le remplacer par un fusible neuf 0 5A 250A ou 10A 250V à action rapide 2 Replacer la coque arrière et fermer avec les même vis qui étaient en place ATTENTION Par sécurité remplacer par exactement les mêmes fusibles Fusible 1 F0 5A 250V 5 x20mm à action rapide Fusible 2 F10A 250V 6 3 x32mm à action rapide Vis Vis Fusible 0 5A F2 Fusible 10A F1 ...

Page 27: ...multimètre et fermer le multimètre dès que l opération est terminée Pour éviter les risques de feu ou de fumée utiliser des fusibles comme ceux indiqués derrière le multimètre PRUDENCE Pour éviter tout dommage statique ou contamination ne pas toucher la planche de composants sans protection statique ...

Page 28: ...customer service e mail service clients kingtony eu Instruction Manual AUTORANGING DIGITAL MULTIMETER ...

Page 29: ......

Page 30: ... Operating Instruction 2 2 1 Scale Ranging 2 2 2 DC Voltage Measurement 2 2 3 AC Voltage Measurement 2 2 4 AC DC Current Measurement 2 2 5 Diode Test 2 2 6 Resistance Measurement 2 2 7 Continuity Measurement 2 2 8 Frequency Measurement 3 BATTERY FUSE REPLACEMENT 3 1 Battery Check Replacement 3 2 FUSE Replacement 4 MAINTENANCE 1 2 3 3 7 10 10 14 14 14 15 16 17 18 19 20 21 21 22 23 ...

Page 31: ......

Page 32: ... acoustic continuity in a circuit when power is applied Never connect the probe to a voltage source when the test leads are plugged into the 10 A input jack Never connect the probe to a voltage source when the function are in uA or mA range Never apply more than rated voltage between any input jack and earth ground Be careful when working with voltages above 60 V dc or 30 V ac rms Such voltages po...

Page 33: ...s To avoid false readings replace the battery immediately When symbol appears Read Safety Information First Dangerous Voltage May Be Present Meter is protected throughout by double insulation or reinforced insulation Comply with IEC1010 1 CAT II When servicing use only specified replacement parts ...

Page 34: ...s II Pollution Degree 2 Altitude up to 2000 meters Indoor use only Relatively humidity 80 max Operation Ambient temp 0 40 C Maintenance Clearing Repairs or servicing not covered in this manual should only by qualified personal Periodically wipe the case with a dry cloth and detergent Do not use abrasives or solvents on this instruments ...

Page 35: ...eading Data Hold Continuity Beeper Diode AC Symbol Manual Range Bargraph Indication DC Symbol Low Battery Auto Range Relative Reading Data Hold Maximum Value Minimum Value Continuity Beeper Diode Alternating current or voltage Direct current or voltage ...

Page 36: ...e polarity Manual Range Bargraph indication Frequency Voltage Millvolt 1 X 10 volt Ampere amps Current Microampere 1 X 10 amp Milliampere 1 X 10 amp Ohm Resistance Kilohm 1 X 10 ohm Resistance Megohm 1X 10 ohm Resistance ...

Page 37: ...ery Life 500hrs typical alkaline Battery Polarity Indicates negative input Auto Power Off Time 30 minutes Operating Temperature and Humidity 0 C to 40 C 32 F to 104 F below80 RH Storage Temperature and Humidity 10 C to 60 C 14 F to 140 F below70 RH Temperature Coefficient 0 1 x Specified accuracy C 18 C or 28 C Weight Approx 220g 7 76oz Dimensions L W H 150mm 72mm 35mm 5 9 2 83 1 38 Accessories Te...

Page 38: ...ltage Auto Range Range Resolution Accuracy Input Impedance Overload Protection 400mV 0 1mV 0 5 2 1000MΩ 750V rms 750V rms 750V rms 750V rms 750V rms 4V 1mV 0 5 2 11MΩ 40V 10mV 0 5 2 10MΩ 400V 100mV 0 5 2 10MΩ 600V 1V 0 8 2 10MΩ 1 2 Electrical Specifications Accurace specification of reading number of least significant digits at 18 C to 28 C 64 F to 82 F 80 RH Diode Tester Range Resolution Accuracy...

Page 39: ... Burden Voltage Overload Protection 400uA 0 1uA 1 3 5 1 6 5 0 25Vrms 0 5A 250V fast Blow Fuse 4000uA 1uA 1 3 5 1 6 5 1Vrms 0 5A 250V Fast Blow Fuse 40mA 10uA 1 3 5 1 6 5 0 25Vrms 0 5A 250V Fast Blow Fuse 400mA 100uA 1 3 5 1 6 5 1 5Vrms 0 5A 250V Fast Blow Fuse 10A 10mA 1 5 5 1 8 5 0 35Vrms 10A 250V Fast Blow Fuse Accuracy Range Resolution 45Hz 400Hz 400Hz 1KHz Input Impedance Overload Protection 4...

Page 40: ...2 1 5VDC 600Vrms 400KΩ 100Ω 0 75 2 1 5VDC 600Vrms 4MΩ 1KΩ 0 75 2 1 5VDC 600Vrms 40MΩ 10KΩ 1 2 3 1 5VDC 600Vrms Range Resolution Accuracy Sensitivity Overload Protection 4 KHz 1Hz 0 1 1 300mVpp 600V rms 40KHz 10Hz 0 1 1 300mVpp 600V rms 400KHz 100Hz 0 1 1 300mVpp 600V rms 4MHz 1KHz 0 1 1 3Vpp 600V rms 40MHZ 10KHz 0 1 1 3Vpp 600V rms Frequency Auto Range ...

Page 41: ...V Hz mA A IEC 1010 POLLUTION DEGREE 2 F 0 5A 250V F 10A 250V WARNING 600V CAT II 2 PARTS CONTROLS 2 1 Name of Parts and Position LCD Display Measured values unit function and decimal points symbols are displayed 1 2 3 6 7 8 4 5 9 ...

Page 42: ... mode Auto range Manual Range Button Press to select the Manual Range mode and the annunciator turn on and The meter remains in the same range it was In the Manual Range mode each time you press button the range and the input range annunciate increases and a new value is displayed If the meter is in the highest range the next range is change to the lowest range To exit the Manual Range mode and re...

Page 43: ...Press it again to select MIN value and press again to select current value with MAX MIN annunciator blinking Press and hold down button for 1 second to exit the MAX MIN mode AC DC Current Select and Ω Select Button To select function AC or DC in current Ampere range To select continuity measurements or Resistance measurement at range Function Selector Switch For power OFF and selection of desired ...

Page 44: ...ect positive lead red test lead for current measurement below 10A VΩ μA mA Hz Measuring Connector To connect positive lead red test lead for voltage diode frequency microampere milliampere and continuity measurement Note To avoid blowing an input fuse use the 10 A jack until you are sure that the current is less than 400mA When Doing Current Measurement Tilt stand 7 8 9 10 ...

Page 45: ...he rotary switch 2 2 2 DC Voltage Measurements WARNING Maximum Input Voltage is 600V AC DC Do not attempt to Take any voltage measurement that may exceed to avoid Electrical shock hazard and or damage to this instrument Connect red test lead to V jack and black test lead to COM jack Set Range Switch to V range Connect the test leads IN PARALLEL to the circuit being measured Read the Voltage value ...

Page 46: ... jack Set Range Switch to V range Connect the test leads IN PARALLEL to the circuit being measured Read the Voltage value on LCD Maximum Input Voltage is 600V AC DC Do not attempt to Take any voltage measurement that may exceed to avoid Electrical shock hazard and or damage to this instrument 1 2 3 4 ...

Page 47: ... desired A range and press DC AC button to select AC DC function Cut the power to the circuit to be tested and Connect the instrument IN SERIES with the circuit with the black test lead on the negative side and the red lead on the positive side being measured Apply power and read the ampere value on LCD To avoid injury do not attempt a current measurement if the open circuit voltage exceeds the ra...

Page 48: ...ad to the cathode side of the diode being tested Read forward Voltage V value on LCD If the polarity of test leads are reversed with diode polarity the digital reading show OL This can be used for distinguishing anode and cathode terminal of a diode Before taking any in circuit measurement remove power from the circuit being tested and discharge all capacitors in the circuit 1 2 3 4 5 3 ...

Page 49: ...ad to COM jack Set Range Switch to Ω range and press button to Ω function Connect test lead to the circuit being measured and read the resistance value on LCD Before taking any in circuit measurement remove power from the circuit being tested and discharge all capacitors in the circuit 1 2 3 ...

Page 50: ...harge all capacitors Connect test lead to the circuit being measured When the impedance between the test jack is lower than 40Ω it will activate a continuous beeper 2KHz Note Continuity Test is available to check open short of the circuit Before taking any in circuit measurement remove power from the circuit being tested and discharge all capacitors in the circuit Open circuit Short circuit 1 2 3 ...

Page 51: ...ency Measurements Connect red test lead to Hz jack and black test lead to COM jack Set Range Switch to Hz range Connect the test lead IN PARALLEL to the circuit being measured Read the frequency value on LCD 1 2 3 4 ...

Page 52: ...type AAA 1 5V is Required 2 Set Range Switch to OFF position Use a screwdriver to remove the rear cover Take out the battery and replace them with two new batteries of type AAA1 5V 3 Place back the rear cover and secure it with the original screw To prevent electrical hazard or shock turn off multimeter and disconnect test leads before removing back cover ...

Page 53: ...function fuse and replace it with a new fuse rated 0 5A 250A or 10A 250V of fast blow type 2 Place back the rear cover and secure it with the original screw WARNING For safety use exact replacement Fuse 1 F0 5A 250V 5Ø 20 mm Fast blow type Fuse 2 F10A 250V 6 3Ø 32 mm Fast blow type screw screw 0 5A fuse F2 10A fuse F1 ...

Page 54: ... before opening the case and close the case before using the meter To prevent fire and possible arc flash use fuses with ratings shown on the back of the meter Caution To avoid contamination or static damage do not touch the circuit board without proper static protection ...

Page 55: ...customer service e mail service clients kingtony eu Manual de instrucciones POLÍMETRO DIGITAL ...

Page 56: ......

Page 57: ...la medición 2 2 2 Medición de tensión DC 2 2 3 Medición de tensión AC 2 2 4 Medición de intensidad AC DC 2 2 5 Verificación del diodo 2 2 6 Medición de resistencia 2 2 7 Medición de corriente continua 2 2 8 Medición de frecuencia 3 Sustitución de pilas y fusibles 3 1 Comprobación y sustitución de pilas 3 2 Sustitución de fusibles 4 Mantenimiento 1 3 3 7 10 10 14 14 14 15 16 17 18 19 20 21 21 22 23...

Page 58: ......

Page 59: ...stencia y no comprobar nunca la continuidad acústica sobre un circuito bajo tensión No conectar nunca la sonda a una fuente de tensión cuando los cables de prueba están conectados a la toma 10A No conectar nunca la sonda a una fuente cuando la función está sobre uA o mA No aplicar nunca más que la tensión evaluada entre la toma y el suelo Tener cuidado cuando trabaje con tensiones superiores a 60V...

Page 60: ...incorrectas cambiar las pilas en cuanto aparezca el icono Leer detenidamente las precauciones de utilización Posibilidad de tensión peligrosa polímetro protegido por un doble aislamiento o por un aislamiento reforzado Comply with IEC1010 1 CAT II Cuando repare el aparato utilice únicamente piezas de recambio homologadas ...

Page 61: ...ta 2 000 m de altitud Solamente utilización en el interior Tasa de humedad 80 maxi Temperatura ambiente 0 40 C Conservación y limpieza Las reparaciones y conservación que no figuren en este manual deberán realizarse por una persona cualificada Limpiar periódicamente el aparato con un trapo limpio y detergente No utilizar nunca productos abrasivos o disolventes sobre los componentes ...

Page 62: ...lativa Toma de datos Sonería continua Diodo Símbolo AC Modo manual Indicaciones con barras Símbolo DC Batería baja Modo automático Lectura relativa Toma de datos Valor máximo Valor mínimo Sonería continua Diodo Corriente alterna o tensión Corriente continua o tensión ...

Page 63: ...Modo manual Indicaciones con barras Frecuencia Tensión Mil voltios 1 X 10 volt Amperio amps Microamperio 1 X10 6 amp Miliamperio 1X10 3 amp Ohmios Resistencia Kilohmios 1 X 103 ohm Resistencia Megohmios 1X106 ohm Resistencia ...

Page 64: ... 1 5V tipo AAA Duración de las pilas 500 h aprox alcalinas Polaridad indica la polaridad negativa Parada automática al cabo de 30 mn Temperatura y humedad de funcionamiento de 0 C a 40 C de 32 F a 104 F por debajo del 80 RH Temperatura y humedad de almacenamiento de 10 C a 60 C de 14 F a 140 F por debajo del 70 RH Temperatura Coeficiente 0 1 x Specified accuracy C 18 C or 28 C Peso aproximadamente...

Page 65: ...ión DC modo auto Franja Resolución Precisión Entrada impedancia Protección 400mV 0 1mV 0 5 2 1000MΩ 750V rms 750V rms 750V rms 750V rms 750V rms 4V 1mV 0 5 2 11MΩ 40V 10mV 0 5 2 10MΩ 400V 100mV 0 5 2 10MΩ 600V 1V 0 8 2 10MΩ 1 2 Especificaciones eléctricas Especificaciones de exactitud de la medición número indicado en pantalla de 18 C a 28 C y por debajo del 80 RH Prueba del diodo Franja Resolució...

Page 66: ...Hz 1KHz Protección 400uA 0 1uA 1 3 5 1 6 5 0 25Vrms 0 5A 250V Fusible rápido 4000uA 1uA 1 3 5 1 6 5 1Vrms 0 5A 250V Fusible rápido 40mA 10uA 1 3 5 1 6 5 0 25Vrms 0 5A 250V Fusible rápido 400mA 100uA 1 3 5 1 6 5 1 5Vrms 0 5A 250V Fusible rápido 10A 10mA 1 5 5 1 8 5 0 35Vrms 10A 250V Fusible rápido Precisión Franja Resolución 45Hz 400Hz 400Hz 1KHz Entrada impedancia Protección 400mV 0 1mV 1 5 45Hz 1...

Page 67: ... 2 1 5VDC 600Vrms 400KΩ 100Ω 0 75 2 1 5VDC 600Vrms 4MΩ 1KΩ 0 75 2 1 5VDC 600Vrms 40MΩ 10KΩ 1 2 3 1 5VDC 600Vrms Franja Resolución Precisión Sensibilidad Protección 4 KHz 1Hz 0 1 1 300mVpp 600V rms 40KHz 10Hz 0 1 1 300mVpp 600V rms 400KHz 100Hz 0 1 1 300mVpp 600V rms 4MHz 1KHz 0 1 1 3Vpp 600V rms 40MHZ 10KHz 0 1 1 3Vpp 600V rms Frecuencia modo auto ...

Page 68: ...mA A IEC 1010 POLLUTION DEGREE 2 F 0 5A 250V F 10A 250V WARNING 600V CAT II 2 Elementos y comandos 2 1 Nombre de las piezas y posición Visualización LCD Se visualizan los valores medidos unidades funciones y símbolos 1 2 3 6 7 8 4 5 9 ...

Page 69: ...undo para salir del modo relativo Pulsador modo auto modo manual Presionar el pulsador para seleccionar el modo manual se visualizará el icono y el polímetro se mantendrá en el modo que estaba En modo manual cada vez que aprieta el pulsador la franja aumenta y se visualiza un nuevo valor Si el polímetro está sobre la franja más grande la próxima franja será la más pequeña Para salir del modo manua...

Page 70: ...e nuevo para seleccionar el valor MIN y otra vez para validar el valor el icono parpadea Mantener pulsado durante 1 segundo para salir del modo Pulsador AC DC y Ω Select Button Para seleccionar la función Ac o DC de la franja del amperio Para seleccionar la medición continua o la medición de resistencia del modo Función selector del conmutador Para apagar y seleccionar la franja de la función dese...

Page 71: ...ble positivo cable de prueba rojo y medir la corriente hasta 10A Conector de medición VΩ μA mA Hz Para conectar el cable positivo cable de prueba rojo y para la medición de la tensión diodo frecuencia miliamperio y continuidad Nota Para evitar quemar un fusible utilizar la salida 10A cuando esté seguro que la corriente está por debajo de 400mA cuando mida la corriente continua Soporte de inclinaci...

Page 72: ...lsador central 2 2 2 Medición de tensión DC ATENCIÓN La tensión de entrada máxima es de 600V AC DC No intente tomar la medición de una tensión superior con el fin de evitar riesgos de electrocución y o desperfectos del aparato Conectar el cable de prueba rojo a la toma V y el cable de prueba negro a la toma COM Posicionar el pulsador central sobre el modo V Conectar los cables de prueba en paralel...

Page 73: ...pulsador central sobre el modo V Conectar los cables de prueba en paralelo al circuito que se va a medir Anotar el valor de la tensión indicada en pantalla La tensión de entrada máxima es de 600V AC DC No intente tomar la medición de una tensión superior con el fin de evitar riesgos de electrocución y o desperfectos del aparato 1 2 3 4 ...

Page 74: ...l sobre el modo A y apretar el pulsador DC AC para elegir la función AC DC Cortar la corriente del circuito a probar y conectar el aparato EN SERIE sobre el circuito con el cable de prueba negro sobre el polo negativo y el cable de prueba rojo sobre el polo positivo a medir Aplicar la corriente y leer el valor en la pantalla Para evitar desperfectos no intente medir la corriente si el circuito abi...

Page 75: ...y el cable de prueba negro del lado cátodo del diodo a probar Leer el valor de la tensión V en pantalla La polaridad de los cables de prueba está invertida con la polaridad del diodo la pantalla indica OL No puede distinguir la terminación ánodo y cátodo de un diodo Antes de tomar la medición sobre un circuito quitar la corriente del circuito a probar y descargar todos los condensadores sobre el c...

Page 76: ...a COM Posicionar el pulsador central en modo Ω y apretar el pulsador para la función Ω Conectar el cable de prueba al circuito a medir y leer el valor de resistencia en pantalla Antes de tomar la medición sobre un circuito quitar la corriente del circuito a probar y descargar todos los condensadores sobre el circuito 1 2 3 ...

Page 77: ... los condensadores Conectar los cables de prueba al circuito a medir Cuando la impedancia entre las tomas de prueba es inferior a 40Ω se puede activar una sonería continua 2Khz Nota el test de continuidad permite saber si el circuito está abierto o corto circuitado Antes de tomar la medición sobre un circuito quitar la corriente del circuito a probar y descargar todos los condensadores sobre el ci...

Page 78: ...nectar el cable de prueba rojo a la toma Hz y el cable de prueba negro a la toma COM Seleccionar el modo Hz con el pulsador central Conectar los cables de prueba en paralelo al circuito Leer el valor de la frecuencia en pantalla 1 2 3 4 ...

Page 79: ... tipo AAA de 1 5V 2 Pulsador central en OFF Utilizar un destornillador para sacar la tapa trasera Quitar las pilas usadas y cambiarlas por pilas nuevas tipo AAA de 1 5V 3 Volver a poner la tapa trasera y cerrar con los mismos tornillos que estaban Con el fin de evitar una electrocución poner el polímetro en OFF y desconectar los cables de prueba antes de quitar la tapa trasera ...

Page 80: ...o y cambiarlo por uno nuevo 0 5A 250A o 10A 250V de acción rápida 2 Volver a poner la tapa trasera y cerrar con los mismos tornillos que estaban ATENCIÓN Por seguridad cambiarlos por exactamente los mismos fusibles Fusible 1 F0 5A 250V 5 x20mm de acción rápida Fusible 2 F10A 250V 6 3 x32mm deacciónrápida Tornillo Tornillo Fusible 0 5A F2 Fusible 10A F1 ...

Page 81: ...o y cerrar el polímetro en cuanto se haya terminado la intervención Para evitar cualquier riesgo de incendio o de humareda utilizar fusibles como los indicados en la parte trasera del polímetro PRECAUCIÓN Para evitar cualquier desperfecto estático o contaminante no tocar la placa de componentes sin protección estática ...

Page 82: ...http www kingtony eu 8909DM1371KT ...

Reviews: