IDEAL INDUSTRIES, INC. 
TECHNICAL MANUAL 
MODEL:  61-700 
MODEL:  61-701 
MODEL:  61-702 
MODEL:  61-704 

 
 
 
The Service Information provides the following information: 

  

 Precautions and safety information 

•   Specifications     
•   Performance test procedure 
•   Calibration and calibration adjustment procedure 
•   Basic maintenance (replacing the battery) 
 

 

 

Form number:  TM61700-1-2-4 
Revision: 4. Date:  Sept 2004

 

 
Form number TM61700-1-2-4 

Rev 4 September 2004 

Summary of Contents for 61-704

Page 1: ...mation provides the following information Precautions and safety information Specifications Performance test procedure Calibration and calibration adjustment procedure Basic maintenance replacing the...

Page 2: ...iance 2 Specifications 3 General Specification 3 Voltage Specifications 4 Current Specifications 4 Resistance Specifications 4 Frequency Specification 4 Capacitance Specifications 4 Diode Continuity S...

Page 3: ...al If you do not do so the protection provided by the meter may be impaired Read the Safety Information page before servicing this product In this manual a Warning identifies conditions and actions th...

Page 4: ...light will blink if there is Voltage Greater that 30V present at the input terminals o In addition to the LED and audible beep the 61 702 and 61 704 has a tactile vibration when voltage is present NCV...

Page 5: ...kaline 61 702 and 61 704 Low Battery Indicator symbol indicates low battery voltage Auto power off Approximately 60 minutes Dimensions 9 7 H X 3 7 W X 1 8 D 247mm H X 94mm W X 46mm D Maximum Cable Siz...

Page 6: ...ce 200 200K 1 0 3digit Diode Check 1mA 0 6mA Not specified Continuity 100 on Diode Continuity Not specified 61 702 61 704 Function Range Ranges Accuracy 2000mV 200V 50Hz 500Hz 1 2 3digits AC Voltage 2...

Page 7: ...74 1926 61 702 61 704 V AC 2000mV 1900mV AC 1kHz 1857 1943 61 702 61 704 V AC 200V 190V AC 50Hz 187 4 192 6 61 700 61 701 61 702 61 704 V AC 200V 190V AC 500Hz 187 4 192 6 61 700 61 701 61 702 61 704...

Page 8: ...alibrator to warm up Perform calibration at 23 2 C at relative humidity of 70 Temperature stabilization should be reached after 30 minutes 2 Disconnect the test leads and turn the range switch to OFF...

Page 9: ...V AC Calibration 61 704 only Refer to Figure 4A 1 Set the function range to the 2000mV AC 2 Connect the calibrator to the V and COM inputs on the meter 3 Output 1 900 VAC 50Hz Adjust VR5 VR 100 until...

Page 10: ...Page 8 Figure 1 Figure 2A Figure 2B Figure 3A Figure 3B Figure 4A Figure 4B Form number TM61700 1 2 4 Rev 4 September 2004...

Page 11: ...ps head screwdriver to remove the screws on battery cover 3 Remove battery from the battery compartment 4 Install new 9V battery NEDA 1604 An alkaline type is recommended 5 Install new battery into co...