10
®
12" to 15"
12" to
15"
12" to
15"
®
®
Water
CYCLER
Metered
Pool Purifier
TOOLS NEEDED
Pipe Wrench
Hacksaw
Tape Measure
MATERIALS NEEDED
Pipe Thread
Sealant
Primer and
PVC Cement
Two 2” Threaded
x 2” or 1½” Slip
male adapters
(not Included)
SECURE CYCLER
1.
2.
For better stability, New
Water Cycler may be
mounted on a treated wood
base using
Phillips pan
head screws,
one in front
and one in back. If you have
questions about stability,
please contact your dealer
or King Technology.
In-line Installation - Model 400
OR
Do NOT install New Water
Cycler Model 400 off-line.
Bi-fl ow valve design allows
installation in either fl ow
direction.
Following pipe thread sealant
directions, brush sealant onto
New Water Cycler threads
in both ports and both male
adapters.
DO NOT USE
PIPE THREAD TAPE
Screw a male adapter
into each port of New Water
Cycler. Hand tighten. Finish
tightening by turning
1 to 2 revolutions
with a pipe
wrench.
DO NOT OVER
TIGHTEN.
Insert PVC pipe into male
adapters with a twisting
action. Hold in place
5 to 10 seconds to bond.
To prevent damage to
heaters or fi lters, see your
dealer about installing a
corrosion resistant check
valve
which will reduce the
back fl ow of chlorine gas
when the Cycler is turned off.
3.
4.
5.
6.
Primer
Measure the distance
between New Water Cycler
male adapters and cut out a
section of pipe 3” less than
that dimension.
Following primer directions,
brush primer on the inside of the
male adapters and to ends of
pipe. Repeat this process with PVC
cement following manufacturer’s
directions on that product.
Allow a minimum
of 12” above and
on each side of
New Water Cycler
to ensure room for
easy replacement
of New Water
Cycler Pac.
Primer
PVC
Cement
PVC
Cement
Do NOT install in copper pipe as
chemical corrosion may lead to pipe
failure.
The New Water Cycler should always be installed
between the fi lter and pool (or between heater and
pool if applicable).
Never install New Water Cycler
before the heater or damage to the heater could
occur.