A Top Safety and Protection Solution In The Worldwide!
www.GSMalarmsystem.com
King Pigeon Hi-Tech. Co., Ltd. Page
25
of 30 Ver 1.1 File No.: S1000012
sensors to the control units, please help to see below:
9.1 Prepare the RF Sensors of PT2262 IC Code
1) Prepare the RF sensors, Open the back cover of the Wireless sensor
carefully;
2) Locate the IC boards black jumpers, labeled A0-A7 and D0-D3.
3) Configured the A0~A7 and D0~D3 different from each wireless
sensors(Includes wireless door sensor, wireless smoke sensor,
wireless gas leakage sensor, wireless pir motion sensor and so on). If
configured the A0~A7 and D0~D3 are the same, the system will treat
them as the same one sensor.
4) Also, please check the Resistors value is 3.3M Ohm, there’re 3
Jumpers, 1.5M,3.3M, and 4.7M. if you select incorrect value, the
wireless distance usually very short or can not learn to the alarm panel.
9.2 Enter the RF Sensor Adding Menu.(See 6.2.2.1 Add/Del RF Parts)
Select the Zone number, press Ok, finished it then press OK to select
the Normal Type Or Stay Type, then following the instruction:
1.Turn
On the Device
, means trigger the RF sensor, the system will show a
code, then
press Enter Key
on the Keyboard. The system will ask
you repeat the operation, so please trigger RF sensor again, when
you see the Code, then press the Enter Button on the Keyboard, the
system will display
Saved OK
. It means the wireless sensor added to
the system. Repeat this operation to add other wireless sensors.
Notice: