PLC Data acquisition protocol conversion gateway
-D225
Mitsubishi programming software The domain name of the Internet IP address (as shown in the
figure is the peanut shell dynamic domain name of the router system service), the port number is
the port number of the internal port mapped to the external port when configuring the router
virtual server (the external port number), (5) serial port configuration Fill in the parameters
according to the parameters of the serial port connected to Mitsubishi FX3U, (6) IP address
configuration, according to your own needs, whether to modify it, (7)
After configuration, you need
to click save parameters, and click the "restart" button to restart the device or D225 device after
the save is successful Power off, power on and restart, the modified configuration will take effect
The company's virtual serial port software configuration is as follows
Operating instructions: (1) Open the virtual serial port software,click the”English”, click the "Add"
button, (2) According to the computer that opened the Mitsubishi programming software, and the
unused COM port, fill in by yourself, (3) Select TCP SERVER for the communication protocol, (4)
Configure the internal IP address and port number of the router virtual server when the IP address
and port number are used, (5) Click "Apply" to do it
After configuring the configuration of D225 configuration software and virtual serial port
software, remote debugging can be realized.
Mitsubishi programming software realizes remote debugging operation steps as follows:
Operation instructions: (1) Open the Mitsubishi programming software, create a project, click the
connection target, and select the COM port configured by the virtual software as the COM port. (2)
Click "Communication Test", (3) If remote debugging is possible, the "CPU Model" will be displayed,
and communication is not possible, and communication failure will be prompted.