Pages 26 Total 58
Shenzhen King Pigeon Hi-Tech Co.,LED
Ver 1.2
PLC Data acquisition protocol conversion gateway
-D225
5.1.3.3
The communication connection configuration with D225
is as folows
Operation instructions: (1) Click "Connect…" of "Connection" to pop up the connection
configuration box, (2) The communication protocol with D225 is: Modbus TCP, (3) Fill in the address
of the D225 device, note: the address should be the same as [on the D225 configuration software
The [IP address] configuration of the network settings is the same, (4) fill in the port number of the
D225 device, note: the port number must be consistent with the [port] configuration of the
[protocol parameter] on the configuration software, the port number here is not [service settings]
[Port Number], (5) Other options can be defaulted or modified according to your own needs. Click
"OK" to communicate with D225 to collect data on FX3U
5.1.3.4
Comarison of the data collected by Modbus Poll and the
data checked by the programming software
The data collected by Modbus Poll is as follows (click "Communication" of "Display" to view the
detailed data communication information)