background image

eLeCTrICAL INFOrMATION

WArNING

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN SERIOUS

INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE EDGE SANDER DISCONNECTED FROM THE POWER SOURCE.

FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

POWer SUPPLY

WArNING:

YOUR EDGE SANDER MUST BE CONNECTED TO A

220V, 15-AMP. MINIMUM BRANCH CIRCUIT. FAILURE TO CONNECT

IN THIS WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE.

GrOUNdING

This  Edge  Sander  must  be  grounded.  If  it  should  malfunction  or

breakdown, grounding provides a path of least resistance for electric

current,  to  reduce  the  risk  of  electric  shock.  This  Edge  Sander  is

equipped with a cord having an equipment-grounding conductor. Once

a plug is installed, the plug must be plugged into an appropriate outlet

that is      properly installed and grounded in accordance with all local

codes and ordinances.

WArNING: 

TO MAINTAIN PROPER GROUNDING OF YOUR EDGE

SANDER, DO NOT REMOVE OR ALTER THE PLUG GROUNDING

PRONG IN ANY MANNER.

Not all outlets are properly grounded. If you are not sure if your outlet

is properly grounded, have it checked by a qualified electrician.

WArNING:

IF NOT PROPERLY GROUNDED, THIS EDGE SANDER

CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED

IN DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER

CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED

IMMEDIATELY.

220V OPerATION

A  220V  plug  is  not  supplied  with  this  Edge  Sander  and  must  be

purchased at your local hardware store. The 220V plug must be a CSA

listed plug suitable for 220V operation. This plug is illustrated in Fig.1.

Contact your authorized service centre or qualified electrician to install

the plug.

eXTeNSION COrdS

WArNING!

IT IS NOT RECOMMENDED TO USE AN ExTENSION

CORD, BUT IF IT IS NECESSARY, READ THE FOLLOWING.

The  use  of  any  extension  cord  will  cause  some  loss  of  power. 

Depending on the length of extension cord needed, use the table (Fig.2)

to determine the minimum wire gauge (A.W.G-American Wire Gauge).

Use only 3-wire extension cords which have 3-prong grounding type

plugs and 3-hole receptacles which accept the tool’s plug.

For circuits that are further away from the electrical circuit box, the wire

thickness must be increased proportionately in order to deliver ample

voltage  to  the  Edge  Sander  motor.  The  smaller  the  gauge  of  the 

extension cord, the thicker it will be in diameter. Refer to Fig.2 for wire

length and size.

MAGNeTIC SWITCH ANd eMerGeNCY STOP bUTTON

Starting and Stopping the edge Sander

The magnetic switch (A) Fig.3 is located on the front right side of the

sander. To turn the sander “On” press the green button (B). To stop the

sander, push the red emergency stop button (C). Once you push down

on the emergency stop button (C), twist the button clockwise until it

pops up, only then will you be able to restart the sander.

FIGUre 2

PrOPerLY GrOUNded 

220V OUTLeT

CUrreNT CArrYING PrONGS

GrOUNdING PrONG

FIGUre 1

LENGTH OF

ExTENSION CORD

0-25 FEET

26-50 FEET

51-100 FEET

WIRE GAUGE REQUIRED

(AMERICAN WIRE GAUGE)

220V LINES

NO.16

NO.14

NO.12

FIGUre 3

Summary of Contents for KC-108-OSC

Page 1: ...INSTrUCTION MANUAL MOdeL KC 108 OSC 6 x 108 OSCILLATING edGe SANder COPYRIGHT 2016 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 04 2017 ...

Page 2: ...d lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with your dated proof of purshase to an authorized King Canada service centre Contact your retailer or visit our web site...

Page 3: ...glasses only have impact resistant lenses they are NOT safety glasses Also use a face or dust mask if cutting operation is dusty 13 dON T OVerreACH Keep proper footing and balance at all times 14 MAINTAIN MACHINe WITH CAre Keep machine clean for best and safest performance Follow instructions for lubricating and changing accessories 15 dISCONNeCT MACHINe Before servicing when changing accessories ...

Page 4: ...ith this Edge Sander and must be purchased at your local hardware store The 220V plug must be a CSA listed plug suitable for 220V operation This plug is illustrated in Fig 1 Contact your authorized service centre or qualified electrician to install the plug eXTeNSION COrdS WArNING IT IS NOT RECOMMENDED TO USE AN ExTENSION CORD BUT IF IT IS NECESSARY READ THE FOLLOWING The use of any extension cord...

Page 5: ...x cover 12 Magnetic safety switch 13 Enclosed cabinet 14 Leveling Fixing bolt 1 of 4 15 Main table height adjusting knob 16 Main table lock knob 1 of 2 17 End table support 18 End table lock handle 19 End table SPeCIFICATIONS MODEL KC 108 OSC Belt 6 x 108 Oscillating stroke 1 4 Table size front 37 x 7 3 4 Table size side 19 x 11 3 4 Belt speed 3 150 SFPM Motor 10 Amp 220V Voltage 220V 1 phase 60 H...

Page 6: ...life 6 The front main table A Fig 5 can also be inclined left or right to allow sanding irregular workpieces Loosen the two lock knobs B and raise or lower one end of the front main table Retighten the two lock knobs B to secure the table position INSTALLING ANd AdJUSTING THe HeIGHT OF THe eNd TAbLe 1 Locate the end table A Fig 6 inside the enclosed cabinet 2 The end table support B needs to be un...

Page 7: ...onds and observe the tracking of the sanding belt Repeat until sanding belt is tracking properly AdJUSTING THe STeeL PLATeN Warning Disconnect power from power source before attempting to adjust this edge sander The steel platen A Fig 10 should be positioned 1 8 to 1 4 in front of the drive roller and the idle roller The steel platen is set properly at the factory but after time an adjustment may ...

Page 8: ...uire replacement once visible signs of wear are apparent To change graphite pad 1 Following the instructions for removing the sanding belt 2 Pull the old graphite pad A Fig 13 off the steel platen A strong solvent may be required to unglue the graphite pad from the steel platen 3 Install a new graphite pad on the steel platen Some graphite pads have adhesive backings some will require using contac...