background image

OPERATION

OPERATION

WARNING!

NEVER OPERATE THE AIR CLEANER WITHOUT THE INNER

AND OUTER FILTERS PROPERLY INSTALLED IN THE CABINET.

OPERATING THE CONTROL PANEL

The control panel (A) Fig.6 allows you to manually turn the air cleaner On or Off

and set the motor/fan speed. 

With/Without Remote On Switch

: (B) Fig.6. Select manual operation or remote

control operation.

Thermal overload protector

: When the motor is overloaded the thermal over-

load (C) Fig.6 will trip and the motor will turn off. The air cleaner will need to cool

down before it can be restarted.

Speed adjustment

: The speed setting switch chain (D) Fig.6 turns the air

cleaner On, it also controls the three different motor/fan speed settings (low,

medium, high). Pull the speed setting switch chain repeatedly to cycle through

the speed settings and to turn the air cleaner Off.  

LED On indicator

: (E) Fig.6. Turns on in remote control mode when air cleaner

is in use.

LED Filter Change indicator

: (F) Fig.6. This LED indicator will turn on after ap-

proximately 320 hours of operation, once the LED indicator turns on it is the rec-

ommended time to clean or change the filters.

OPERATING THE REMOTE CONTROL

NOTE: To operate the air cleaner with the remote control, the With/Without

Remote On Switch (B) Fig.6 on the air cleaner must be positioned to the

“With Remote” position, or the remove control will not work. 

On/Timer button

: (A) Fig.7. Press the On button to turn the air cleaner On. To

cycle through the “continuous” mode or the 4 timer settings (2, 4, 6 or 8 hours),

press the On button again until one of the timer LED’s (B) lights up, then use

the up/down buttons (C & D) to select the desired setting.

Off button

: (E) Fig.7. Press the Off button to turn the air cleaner Off.

Speed adjusting buttons

: To cycle through the 3 speed settings (950, 1085,

1400 CFM), turn the air cleaner on, then press the On button again until one of

the speed LED’s (F) lights up, then use the up/down buttons (C & D) to select

the desired speed setting.

CHANGING FILTERS

WARNING!

To reduce the risk of injury, disconnect the air cleaner from the

power source before servicing or changing filters. Failure to comply may cause

serious injury!

The two filters included will eventually need to be cleaned or replaced. The outer

filter can easily be removed by lifting the bottom of the filter and pulling it out of

the air cleaner housing. The inner 3 pocket filter can now be pulled out of the air

cleaner housing in the same way. The filters should be replaced depending on

the amount of usage and the environment of your shop. Clogged filters will re-

duce the amount of air circulation. Replacement filters are availlable at your

nearest KING CANADA retailer.

Replacement filters; 

Model KW-154- 5 micron outer filter

Model KW-155- 1 micron inner 3 pocket filter