SETTING UP THE AIR CLEANER

UNPACKING 
 

The Air Cleaner is shipped complete in one carton. Carefully unpack the Air 
Cleaner and all loose items from the carton. 

WARNING: DO NOT LIFT THE 

AIR CLEANER BY ITS POWER CORD. 

 

 
 

 
 

 
 
 
 
 
 
 
 
 
 
 

WARNING:

 

STYROFOAM BLOCKS PLACED AROUND THE MOTOR AND 

IMPELLOR MUST BE REMOVED BEFORE OPERATING AIR CLEANER.

  

 
1) Pivot the upper and lower filter retaining clips (A) Fig.4 and pull out the outer 

and inner filters (B). 

2) Remove the steel meshing (C) inside the air cleaner and remove the           

styrofoam blocks (D).  

3) Reinstall the steel meshing, inner and outer filters and secure the filters with 

the retaining clips. 

 

SETTING UP THE AIR CLEANER 
 

Operational tips: 
• This Air Cleaner will work best if it is located away from corners and heating/ 

cooling vents. 

• This air cleaner is specifically designed to circulate and filter non-metallic 

dust, which is generated throughout the work area.  

 

Hanging air cleaner from ceiling 

1) This Air Cleaner can be hung from the ceiling. Remove the four large pan 

head screws (A) Fig.5 from the top of the air cleaner housing using a Philips 
screwdriver. 

2) Install the four air cleaner eye bolts (B) Fig.5 to the top of the air cleaner         

housing. 

3) Mount ceiling hooks and chains (not included) properly rated for hanging 

this unit (minimum 60 lbs capacity) in the ceiling to mount the air cleaner. 

 
Mounting air cleaner to ceiling or wall 

1) Four brackets (A) Fig.6 can also be used for mounting to a ceiling or wall. 
2) Place one end of bracket underneath the lip of the air cleaner cabinet (B). 
3) Secure the bracket (A) to the cabinet with two hex. bolts, spring  washers 

and washers (C) as shown in Fig.6. Repeat steps for the remaining three     
brackets. 

4) Secure air cleaner to ceiling or wall with appropriate hardware (not         

included).  

 
WARNING!

 Ceiling hooks  or mounting brackets must be anchored to the 

building structure, which will support a minimum of at least 100 pounds. Never 
mount to drywall or false ceiling grids. Hang/mount unit with a 7ft. clearance 
from the floor.