background image

OPERATION

OPERATION 
WARNING!

  NEVER OPERATE THE AIR CLEANER WITHOUT THE INNER 

AND OUTER FILTERS PROPERLY INSTALLED IN THE CABINET. 
 

Operating the control panel 

 
The control panel (A) Fig.7 allows you to manually turn the air cleaner On or 
Off and set the motor/fan speed.  
 

Fuse

: This Air Cleaner is protected by a fuse (B) Fig.7, in the event of an      

overload, the fuse will burn out and the motor will turn off. The cause for the 
overload will need to be determined and corrected (often the cause is clogged 
filters, or an electrical issue. Replace filters/verify electrical wiring), and the 
fuse will need to be replaced before attempting to use again. 

 
On/Speed button

: (C) Fig.7 The On/Speed button turns the Air Cleaner On, it 

also controls the three different motor/fan speed settings (low, medium, high). 
Press the On/Speed button repeatedly to cycle through the speed settings. The 
selected speed is indicated by the red LED indicators (D) Fig.7.  
 

Off button

: (E) Fig.7 The Off button turns the air cleaner Off. 

 

Operating the remote control

 

 

On/Speed button

: (A) Fig.8 The On/Speed button on the remote control turns 

the air cleaner On, it also controls the three different motor/fan speed settings 
(low, medium, high). Press the On/Speed button repeatedly to cycle through 
the speed settings. The selected speed is indicated by the red LED indicators 
(D) Fig.7 on the control panel. 
 

Timer button

: (B) Fig.8 controls the three different settings which are: 

1H

- The 1hr. LED indicator (F) Fig.7 on the control panel will light up with one 

press of the timer button. The air cleaner will operate for 1 hour and then will 
shut off automatically. 

2H

- The 2hr. LED indicator (F) Fig.7 on the control panel will light up by      

pressing the timer button two times. The air cleaner will operate for 2 hours and 
then will shut off automatically. 

4H

- The 4hr. LED indicator (F) Fig.7 on the control panel will light up by      

pressing the timer button three times. The air cleaner will operate for 4 hours 
and then will shut off automatically. 
 

Off button

: (C) Fig.8 The Off button turns the air cleaner Off. 

 

CHANGING FILTERS 
 
WARNING!

 To reduce the risk of injury, disconnect the air cleaner from the 

power source before servicing or changing filters. Failure to comply may cause 
serious injury! 
 
The two filters included will eventually need to be replaced. The outer filter can 
easily be removed by pivoting the two retaining clips of the cabinet and pulling 
out the outer filter. The inner 3 pocket filter can now be pulled out of the unit. 
The filters should be replaced depending on the amount of usage and the       
environment of your shop. Clogged filters will reduce the amount of air             
circulation. Replacement filters are available at your nearest KING CANADA 
retailer. 

Replacement filters:  

Model KW-141- 5 Micron outer filter 
Model KW-142- 1 Micron inner 3 pocket filter

FIGURE 7

FIGURE 8

PARTS DIAGRAM & PARTS LISTS

 

Refer to the Parts section of the King Canada web site for the most updated parts diagram and parts list.