OPERATION
OPERATION
WARNING!
NEVER OPERATE THE AIR CLEANER WITHOUT THE INNER
AND OUTER FILTERS PROPERLY INSTALLED IN THE CABINET.
Operating the control panel
The control panel (A) Fig.7 allows you to manually turn the air cleaner On or
Off and set the motor/fan speed.
Thermal overload protector
: When the motor is overloaded the reset button
(B) Fig.7 will trip and the motor will turn off. See Electrical Information for more
information.
On/Speed button
: (C) Fig.7 The On/Speed button turns the air cleaner On, it
also contols the three different motor/fan speed settings (low, medium, high).
Press the On/Speed button repeatedly to cycle throught the speed settings.
The selected speed is indicated by the red LED indicators (D) Fig.7.
Off button
: (E) Fig.7 The Off button turns the air cleaner Off.
Operating the remote control
On/Speed button
: (A) Fig.8 The On/Speed button on the remote control turns
the air cleaner On, it also contols the three different motor/fan speed settings
(low, medium, high). Press the On/Speed button repeatedly to cycle throught
the speed settings. The selected speed is indicated by the red LED indicators
(D) Fig.7 on the control panel.
Timer button
: (B) Fig.8 controls the three different settings which are:
1H
- The 1hr. LED indicator (F) Fig.7 on the control panel will light up with one
press of the timer button. The air cleaner will operate for 1 hour and then will
shut off automatically.
2H
- The 2hr. LED indicator (F) Fig.7 on the control panel will light up by
pressing the timer button two times. The air cleaner will operate for 2 hours and
then will shut off automatically.
4H
- The 4hr. LED indicator (F) Fig.7 on the control panel will light up by
pressing the timer button three times. The air cleaner will operate for 4 hours
and then will shut off automatically.
Off button
: (C) Fig.8 The Off button turns the air cleaner Off.
CHANGING FILTERS
WARNING!
To reduce the risk of injury, disconnect the air cleaner from the
power source before servicing or changing filters. Failure to comply may cause
serious injury!
The two filters included will eventually need to be replaced. The outer filter can
easily be removed by pivoting the two retaining clips of the cabinet and pulling
out the outer filter. The inner 3 pocket filter can now be pulled out of the unit.
The filters should be replaced depending on the amount of usage and the
environment of your shop. Clogged filters will reduce the amount of air
circulation. Replacement filters are availlable at your nearest KING CANADA
retailer.
Replacement filters;
Model KW-141- 5 micron outer filter
Model KW-142- 1 micron inner 3 pocket filter
FIGURE 7
FIGURE 8