background image

ELECTRICAL INFORMATION

WARNING!

ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE AIR CLEANER DISCONNECTED FROM THE POWER SOURCE.
FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

GENERAL INFORMATION- 120V single phase operation

This air cleaner comes with a 120V single phase motor. 

WARNING:

YOUR AIR CLEANER MUST BE CONNECTED TO A

110V-120V, 1 PHASE

ELECTRICAL

SUPPLY. FAILURE TO

CONNECT IN THIS WAY CAN RESULT IN INJURY FROM SHOCK OR
FIRE.

This air cleaner is intended for use on an electrical circuit that has an
outlet and a plug which looks like the one illustrated in Fig.1.

WARNING:

DO NOT USE A TWO-PRONG ADAPTOR FOR THEY

ARE NOT

IN ACCORDANCE WITH LOCAL

CODES AND

ORDINANCES. NEVER USE IN CANADA.

GROUNDING

Your air cleaner must be properly grounded. Not all outlets are
properly grounded. If you are not sure if your outlet is properly
grounded, have it checked by a qualified electrician. If it should
malfunction or breakdown, grounding provides a path of least
resistance for electric current, to reduce the risk of electric shock. This
air cleaner is equipped with a cord having an equipment-grounding
conductor and grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.

WARNING: 

TO MAINTAIN PROPER GROUNDING OF YOUR AIR

CLEANER, DO NOT REMOVE OR ALTER THE GROUNDING PRONG
IN ANY MANNER.

WARNING:

IF NOT PROPERLY GROUNDED, THIS AIR CLEANER

CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED
IN DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER
CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.

EXTENSION CORDS

The use of any extension cord will cause some loss of power. Use the
table (Fig.2) to determine the minimum wire size (A.W.G-American Wire
Gauge) extension cord needed. Use only 3-wire extension cords which
have 3-prong grounding type plugs and 3-hole receptacles which
accept the tool’s plug.

For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample voltage
to the air cleaner motor. Refer to Fig.2 for wire length and size.

RESET BUTTON

This air cleaner comes with a thermal overload protector, when the
motor is overloaded the reset button (A) Fig.3 will trip and the motor will
turn off. Allow the motor to cool down for a few minutes before
attempting to restart the air cleaner. Press the rest button (A) and press
the On button (B) to restart air cleaner.

FIGURE 2

FIGURE 1

PROPERLY

GROUNDED OUTLET

CURRENT CARRYING PRONGS

GROUNDING PRONG

FIGURE 3

LENGTH OF

EXTENSION CORD

0-25 FEET

26-50 FEET

51-100 FEET

WIRE SIZES REQUIRED

(AMERICAN WIRE GAUGE)

110V-120V LINES ONLY

NO.16
NO.16
NO.14

Reviews: