Page 1: ...Star MM 224 MiniModus INSTRUCTION MANUAL EN...

Page 2: ...gramming buttons Dip switch function setting Paragraph 4A 5 MEMO Extractable memory Paragraph 13A External Power connection fuse box RX Star radio code receiver 433 920MHz Paragraph 13B Setting trimme...

Page 3: ...izable delay between the wings in closing from 0 to 15 sec by trimmer see paragraph 4B Pause time before automatic reclosing customizable from 0 to 90 sec by trimmer see paragraph 4B Sensibility of th...

Page 4: ...n the other one MOT1 terminal 24 25 must start first Then it will be necessary to regulate the delay between the wings through the trimmer DEL see paragraph 4B If there is only 1 motor connected it mu...

Page 5: ...RADIO again to exit the procedure red LED goes off 3B PEDESTRIAN OPENING START CHANNEL PROGRAMMING PROCEDURE Using this procedure the installer can delete all the previously programmed radio remote c...

Page 6: ...equires the repetition of the learning procedure point 2 because of the change of the manoeuvre time The slowdowns are automatically set in the last 15 of the travel 4B TRIMMER SETTINGS 4A DIP SWITCHE...

Page 7: ...vene stop the motion of the wings which will open again as soon as cleared typical functioning of the photocell If the PHO2 dip switch is set to OFF the safety devices in opening when they intervene i...

Page 8: ...programming procedure verify that The motors shut down a few seconds after the end of the programming procedure The control unit respond to the inputs received by wire START terminal 12 pedestrian ope...

Page 9: ...remote control for the second wing 12a Choose the point of slow down with the button SET or the button 1 of the transmitter for the first wing and with the button RADIO or the button 2 of the remote c...

Page 10: ...by wire the START button or a button in the transmitter 5 The gate begins to open 6 Press the command by wire the START button or the button in the transmitter to set the widening of the pedestrian o...

Page 11: ...is equal to about 0 1 seconds if adjusted to an intermediate position it is equal to about 1 5 seconds while at the maximum the intervention time will be about 3 seconds See also paragraph 11D 8C Tri...

Page 12: ...closing commands neither automatic nor by wire as long as the contact will be opened again The pedestrian opening is a partial opening or total opening if the installer wants it of the wing opened by...

Page 13: ...urrent 11D OBSTACLE DETECTION BY POWER ABSORPTION The control unit has a self test function of the safeties connected to the PHO1 and PHO2 input It switches off the transmitter to check the commutatio...

Page 14: ...gate open warning light The status of the lamp is as follows If the access is closed the light is switched off If the access is open is alight with a fixed light If the access is opening the lamp fla...

Page 15: ...procedure paragraph 5D and reduce at minimum or remove the slowdowns 14F THE AUTOMATION STARTS BUT AT A CERTAIN POINT IT STOPS An external antenna has been connected but the standard cable mounted in...

Page 16: ...King Gates S r l Via A Malignani 42 33077 Sacile PN ITALY Tel 39 0434 737082 Fax 39 0434 785351 e mail info king gates com web www king gates com MADE IN ITALY...