2
SETTINGS AND CONNECTIONS GENERAL DIAGRAM
FORCE /
SPEED
PAUSE
TIME
OBSTACLE
SENSIBILITY
PHO and STP inputs – must
be bridged if not used
NOTE:
The control unit is supplied with a trimmer to adjust the force of the motors set on maximum
value (100%). Maintain this setting, which facilitates installation in difficult conditions (worn-out or not
lubricated hinges, stress points etc.) Afterwards, reduce the force to obtain an operator movement that
is slower and requires less force. After having adjusted the force the learning procedure must be repea-
ted.
� �
��
��
�
� �
PHOTOCELLS
STOP OPEN /
STEP - STEP
MOTOR
24Vdc Max 100W
230 VAC (MAINS)
Install
switch/disconnect
switch 6A (IC=30mA)
24 VDC
BATTERY
(max 7Ah)
TRANSFORMER
230/20VAC
for 24VDC motors
If inputs FC1
and F01 are
not used they
must not be
jumped
1 A
NETWORK
FUSE
ACCESSORIES
FUSE 2A
Courtesy light
24VAC max 10W
Selection of Power supply
for flashing light 12/24V
8A BATTERY
FUSE
Flashing Light
12V - 24V max 5W
LIMIT SWITCH - CLOSING
LIMIT SWITCH - OPENING
FEELER
Signal
Sock