INFORMAZIONI GENERALI
The Star D 500 self-learning control unit has been designed for 24VDC single motor automations, with or without electrical
limit stops and with or without encoder. Its innovative self-learning procedure makes for quick and easy installation and its
three trimmers permit fine adjustment of all main parameters, namely force (or speed), pause time and motor obstacle
detection sensitivity.
MAIN FEATURES
- Command and control of sectional doors, overhead doors, and road barriers in 24VDC
- Management of Encoder and/or Limit stop during opening and closing
- Speed adjustable with FOR trimmer from 50% to 100%
- 0 to 60” stand-by time adjustment via trimmer.
- 0.1 to 3.0” obstacle detection triggering time adjustment via trimmer.
- Softstart during closure (motor starting speed reduced)
- Operating mode: automatic, step by step, step by step with automatic closure, man present, selectable with DIP.
- Courtesy light 24VAC 20W max
- Courtesy light activated with remote control
- Built in 24V battery charger
- STOP input
- Built in 433MHz rolling code receiver with 180 memorisable codes
- 12 or 24VDC flashing light (selectable with jumper)
- Flashing light logic, fixed or flashing, selectable with DIP.
- Safeties test enabled with DIP
- Flash microprocessor re-programmable on-board via serial interface.
- Simplified and professional learning procedure
- Built to European reference Directive Standards (R&TTE 99/05/CE)
TECHNICAL SPECIFICATIONS
Transformer power supply:
230VAC
Control unit power supply:
20VAC
Motor output:
24VDC 100Watt max
Max.current peak of motor:
8 Ampere
Accessory power supply:
12 VDC - 400 mA
Environmental operating temperature:
-20°C / + 55 °C
CONNECTION AND SET UP OF THE CONTROL UNIT
a) Before starting the installation of the Star D 500 control unit please read the “Safety warnings for installation and use”
b) Mount a differential thermo-magnetic circuit breaker 6A (IC=30mA) on the mains supply as specified in the current
reference standards (IC = differential current).
c) Connect the outdoor accessories
d) ATTENTION: Connect the limit switches, if present, otherwise do not bridge inputs FC1 and FO1 in the terminal board.
Connect the encoder, if present, as follows: positive to terminal 8 (+V), negative to terminal 4 (-BAT), signal to terminal 7
(E1).
e) ATTENTION: in the absence of electrical or mechanical limit stops, to define the times of the manoeuvre, proceed as
follows:
Press button 1 on the remote control or the P1/SET pushbutton to stop the manoeuvre in the desired position.
f) Check the correct connection and operation of all the accessories connected to the terminal board.
1