INFORMAZIONI GENERALI

The Star D 500 self-learning control unit has been designed for 24VDC single motor automations, with or without electrical 

limit stops and with or without encoder. Its innovative self-learning procedure makes for quick and easy installation and its 

three trimmers permit fine adjustment of all main parameters, namely force (or speed), pause time and motor obstacle 

detection sensitivity.

MAIN FEATURES

- Command and control of sectional doors, overhead doors, and road barriers in 24VDC

- Management of Encoder and/or Limit stop during opening and closing

- Speed adjustable with FOR trimmer from 50% to 100%

- 0 to 60” stand-by time adjustment via trimmer.

- 0.1 to 3.0” obstacle detection triggering time adjustment via trimmer.

- Softstart during closure (motor starting speed reduced)

- Operating mode: automatic, step by step, step by step with automatic closure, man present, selectable with DIP.

- Courtesy light 24VAC 20W max 

- Courtesy light activated with remote control

- Built in 24V battery charger

- STOP input

- Built in 433MHz rolling code receiver with 180 memorisable codes 

- 12 or 24VDC flashing light (selectable with jumper)

- Flashing light logic, fixed or flashing, selectable with DIP.

- Safeties test enabled with DIP

- Flash microprocessor re-programmable on-board via serial interface.

- Simplified and professional learning procedure

- Built to European reference Directive Standards (R&TTE 99/05/CE)

TECHNICAL SPECIFICATIONS

Transformer power supply: 

 

 

230VAC

Control unit power supply:        

 

20VAC  

Motor output:     

              

 

24VDC 100Watt max  

Max.current peak of motor:  

 

 

8 Ampere  

Accessory power supply: 

 

             12 VDC - 400 mA      

Environmental operating temperature:    

-20°C / + 55 °C

CONNECTION AND SET UP OF THE CONTROL UNIT

a) Before starting the installation of the Star D 500 control unit please read the “Safety warnings for installation and use”

b) Mount a differential thermo-magnetic circuit breaker 6A (IC=30mA) on the mains supply as specified in the current 

reference standards (IC = differential current).

c) Connect the outdoor accessories

d) ATTENTION: Connect the limit switches, if present, otherwise do not bridge inputs FC1 and FO1 in the terminal board. 

Connect the encoder, if present, as follows: positive to terminal 8 (+V), negative to terminal 4 (-BAT), signal to terminal 7 

(E1).

e) ATTENTION: in the absence of electrical or mechanical limit stops, to define the times of the manoeuvre, proceed as 

follows:

Press button 1 on the remote control or the P1/SET pushbutton to stop the manoeuvre in the desired position.

f) Check the correct connection and operation of all the accessories connected to the terminal board.

1

Summary of Contents for Star D 500

Page 1: ...ore installing thoroughly read this manual that is an integral part of this Kit Antoniolli Mario C s a s declines any responsibility in the event current standards in the country of installation are n...

Page 2: ...DIP Safeties test enabled with DIP Flash microprocessor re programmable on board via serial interface Simplified and professional learning procedure Built to European reference Directive Standards R T...

Page 3: ...to obtain an operator movement that is slower and requires less force After having adjusted the force the learning procedure must be repea ted PHOTOCELLS STOP OPEN STEP STEP MOTOR 24Vdc Max 100W 230 V...

Page 4: ...motor turns in reverse invert wires and start procedure again from RESET Adjust trimmers if necessary ATTENTION A trimmer variation FOR speed requires the repetition of the learning procedure from RES...

Page 5: ...ning Adjust trimmers if necessary ATTENTION A trimmer variation FOR speed requires the repetition of the learning procedure from RESET With only encoder present terminate manoeuvre by pressing P1 SET...

Page 6: ...memory During saving the red LED flashes slowly When it is finished the red LED returns to the fixed light status to signal that a new remote control can be entered Memorise all the transmitters by ma...

Page 7: ...educed speed Softstart and then at the speed set with the FOR trimmer if a command is received during closure the control unit commands the complete re opening the closure terminates when the limit st...

Page 8: ...shing light is alternating and therefore a normal lamp without an oscillating circuit can be connected 12 or 24VDC Max 10W SLOW DOWN With the slow down function the door applies a reduced force before...

Page 9: ...nstallation maintenance repairs and cleaning operations must be documented This documentation must be preserved by the user and made available to the personnel responsible for the control WARNINGS FOR...

Reviews: