background image

Before installing the product ascertain that safety conditions are observed according to the law, rules and regulation.

Use personal safety devices and locate warning signs on the motorized gate.          

Unfulfilment of the below listed direction will release the King gates srl from any responsibility for 

damage caused to people or things.

-Ascertain the intigrity of the packing when opening it.

-In case of anomalies in the functioning, turn immediatly off the gear-motor, disconnect electrical power and operate the gate 

manually the problem has been found and salved.

-Do not modify the product in any part.

-Only authorized and qualified staff is alloned to disassemble the product. 

-Prevent any part of the automation from being next to any source of heat or in contact with liquid substances.

-Use only adeguate power supply cables.

-To optimize the functioning of the automation, King gates accessories only.

-Disposal of waste material has to observe local regulations. 

-Installing, testing and first functioning have to observe the laws in force.    

WARNINGS 

MAIN FEATURES 

TYPICAL SYSTEM 

1    Gear-motor 

2    Photocell 

3    Flashing-light 

4    Key selector 

5    Adaptor arm 

Power supply 

 230 

Motor power supply 

 24 

Electrical input 

 0.8 

Working temperature 

 -20 ÷ +55 

10 

Max dimensions sectional doors 

10 

Max dimensions overhead doors 

M8, Z18 

Transmission gear 

9 - 16 

Speed 

60 

414x264x110 

Frequency of use 

37 

Motorgear dimensions 

(Vac 50Hz) 

(Vdc) 

(A) 

(°C) 
(m ) 

(m ) 

(cm/sec.) 

(%) 

(mm) 

Slide thickness 
Limit switch 

(mm) 

Encoder with mechanical stop 

230 

24 

1.3 

9 - 16 

-20 ÷ +55 

17 
14 

M8, Z18 

 

60 

414x264x110 

37 

Encoder with mechanical stop 

Rolls 1200 

Rolls 700

Max thrust 

700

(N) 

1200 

 TECHNICAL SPECIFICATIONS AUTOMATION 

Transformer power supply 

 230 

Control unit power 

 230 

Max current peak from the motor 

Accessories power 

 24 (400mA) 

-20 ÷ +55 

Environmental operating temperature 

230 (max 40W) 

Courtesy light 

Activated by remote control 

Courtesy light operation 

433 MHz incorporated with 180 storable codes

Receiver 

(Vac) 
(Vac) 

(A) 

(Vdc) 

(°C) 

(Vac ) 

24 (max 15W) 

Flash light 

(Vdc) 

Star GDO 100 

Motor output 

24 (max 100Watt) 

(Vdc) 

TECHNICAL SPECIFICATIONS STAR GDO100 

Summary of Contents for ISTBJV01

Page 1: ...ROLLS INSTRUCTION MANUAL UK ISTBJV01...

Page 2: ...1 3 5 2 4 6 F F B A E B C D E E H G...

Page 3: ...7 9 11 8 10 12 I I I L B O O M M N N M M M M N N E A A 18 mm...

Page 4: ...13 14 15 16 17 18 H O P R Q 11 10 09 08 07 06 05 04 03 02 01...

Page 5: ...19 20 R 22 21 24 23...

Page 6: ...only Disposal of waste material has to observe local regulations Installing testing and first functioning have to observe the laws in force WARNINGS MAIN FEATURES Power supply 230 Motor power supply...

Page 7: ...TYPICAL SYSTEM 1 Gear motor 2 Photocell 3 Flashing light 4 Key selector 5 Adaptor arm 1 2 2 3 4 1 2 2 3 4 5...

Page 8: ...05 Prepare the two profiles F and the joint G supplied fig 06 Join the two guides and the joint firmly together with the fastenings supplied H fig 06 Insert the screw M8x70 E into the bracket I Inser...

Page 9: ...keep it released even after closing the gate OPERATION The user that exits from the garage can close the gate and re enter without having to repeat the release operation The automation release must be...

Page 10: ...s in opening contact PHO2 STOP contact Terminals 4 6 common START contact 12 Vdc power supply Safety autotest 12Vdc Terminals 1 8 common Safety devices in closing contact PHO1 24Vdc power supply FLASH...

Page 11: ...red LED goes off Make a transmission pressing the desired key on the transmitter During entry the red LED flashes and then remains steady on once the code is stored Power up the control unit and put D...

Page 12: ...chanical stop 8 The control unit briefly open 9 Pause for one second 10 The door close until mechanical stop Yellow LED switches off END of learning procedure 1 Put the door in an intermediate positio...

Page 13: ...or 2 sec Yellow led flashes 3 Within 5 seconds press the programming button P1 SET for 1 sec Yellow LED turned on 4 The control unit briefly open Yellow LED stays on 5 The door close until mechanical...

Page 14: ...IP 2 in the ON position The step step logic is OPEN STOP CLOSE STOP When the opening manoeuvre has been completed and the pause time set on the PAU trimmer has elapsed the control unit effects automat...

Page 15: ...ntion delay can be set between 0 1 and 3 seconds Thus if the trimmer is set at the minimum then the intervention time is equal to about 0 1 seconds if adjusted to an intermediate position it is equal...

Page 16: ...p input stops all the function To resume the cycle the stop must be deactivated and another command given BACK UP BATTERIES STOP INPUT SIGNALLING LED T fa F A The control unit has two output terminals...

Page 17: ...e of the fastenings wear on the moving parts pulleys carriages and the belt tension Fuse 2A Accessories LED Signal Line fuse 2A MAINTENANCE Motor and encoder connection SW Secondary transformer Blue C...

Page 18: ...King Gates S r l Via A Malignani 42 33077 Sacile PN ITALY Tel 39 0434 737082 Fax 39 0434 785351 e mail info king gates com web www king gates com MADE IN ITALY...

Reviews: