background image

INSTRUCTION MANUAL

Motorgear for swing gates

MADE IN ITALY

EN

Intro

KING gates

 - Brand of Antoniolli Mario & C. s a s

Via A. Malignani, 42 - 33077 Sacile (PN) ITALY

Tel. +39 0434 737082 - Fax +39 0434 783382

e-mail: [email protected]   web: www.king-gates.com

STAMP

COMPANY:

PLACE:

PROVINCE:

TELEPHONE NUMBER:

CONTACT PERSON:

INSTALLER REFERENCE

PRODUCER REFERENCE

Summary of Contents for Intro 230

Page 1: ...INSTRUCTION MANUAL Motorgear for swing gates MADE IN ITALY EN Intro...

Page 2: ...1 TYPICAL AUTOMATION 1 Operators 2 Flashing warning light 3 Antenna 4 Photocell 5 Small columm 6 Key switch 7 Electronic control unit 8 Warning sign 9 Stop locks 2...

Page 3: ...imensions 230 V 230 V 200 W 1 3 A 12 5 nF 20 55 C IP67 40 340x170x410 mm 10 Kg 2 5 m 230 V 24 V 50 W 2 5 A 20 55 C IP67 60 340x170x410 mm 10 Kg 2 5 m Intro 230 Intro 24 2 TECHNICAL DATA 3 DIMENSIONS 7...

Page 4: ...24 2 x 0 75 mm 2 x 0 75 mm 4 x 0 75 mm 230V 3 x 1 5 mm 2 3 x 1 5 mm Intro 230 2 2 2 2 2 STAR BOX Phase 1 Phase 2 Common Earth Black wire Brown wire Gray wire Yellow green wire INTRO 230 CONNECTION Pha...

Page 5: ...Before assembling the automatism check that the gate is in perfect working order hangs well on its hinges and is suitably lubricated It must also comply with the safety standards in force in the count...

Page 6: ...the tubes for water drainage in the prepared holes A Insert the sheath for laying the power cables and limit switch B Note while positioning the box keep in mind the minimum distance there must be be...

Page 7: ...6 OPERATOR AND LEVERS 6 1 ASSEMBLING Place the operator in the box and fasten it with the nuts provided Insert the ball in the pin located on the box and fit the gate anchorage lever L1 L1 7...

Page 8: ...Insert the cover and fasten it with the screws provided Position the gate wing and the lever L1 so that they are perfectly aligned and fasten them by welding or similar Insert the lever L3 onto the mo...

Page 9: ...L1 C D 6 3 EMERGENCY RELEASE PROCEDURE Insert the key C provided into the appropriate hole D on the lever L1 Turn the key clockwise by about 45 9...

Page 10: ...lation All installation maintenance repairs and cleaning operations must be documented This documentation must be preserved by the user and made available to the personnel responsible 7 3 WARNINGS FOR...

Page 11: ...1 2 3A 3B 4A 4B 5 MOTOR VERSION Intro 230 Intro 24 Intro 230 Intro 24 Intro 230 Intro 24 Intro 230 Intro 24 Intro 230 Intro 24 CODE RI01LC RI02LM RI230MO RI24MO RI01MR RI02MR RI01CA 1 2 3B 3A 5 4A 4B...

Page 12: ...C s a s Via A Malignani 42 33077 Sacile PN ITALY Tel 39 0434 737082 Fax 39 0434 783382 e mail info king gates com web www king gates com STAMP COMPANY PLACE PROVINCE TELEPHONE NUMBER CONTACT PERSON IN...

Reviews: