Adding Salt

Ensure that the salt level in the brine tank is always above the water line. 

DO 

NOT USE ROCK SALT

.

Water Pressure

Inlet water pressure range of 20-125 psi is required for regeneration valve to 

operate effectively.

Electrical Facilities

An uninterrupted alternating current (A/C) supply is required. Please make 

sure voltage supply is compatible with unit before installation. 

A backup 9-Volt 

battery should be installed and properly maintained (replace yearly).

Existing Plumbing

Condition of existing plumbing should be free from lime and iron buildup. 

Replace piping that has heavy lime and/or iron buildup. If piping is clogged with 

iron, install a separate iron filter unit ahead of the water softener.

By-pass Valves

Always install a by-pass valve if unit is not equipped with one. If valve is leaking, 

turn by-pass from Service to the By-pass position.

NOTE:  A check valve (included in extension pipe feeding by-pass valve) must be 

installed on the inlet to the unit.

NOTE:  

If the valve continues to leak after turning the by-pass to By-pass position, 
shut off the main water line and call your local service technician (preferably 
the one who installed the system) IMMEDIATELY.

CAUTION

• Do not exceed water pressure of 125 psi.

• Do not exceed water temperature of 110°F.

• Do not subject unit to freezing conditions.

SERVICE 

OFF  

BYPASS

Summary of Contents for 17214

Page 1: ...ine PRO Timered and Metered Softeners Owner s Manual Model Product Numbers PRO 0840ST 17214 PRO 0840S 17218 PRO 1040ST 17215 PRO 1040S 17219 PRO 1054ST 17216 PRO 1054S 17220 PRO 1354ST 17217 PRO 1354S...

Page 2: ......

Page 3: ...n wonder how you ever lived without it Improving your water with a Kinetico Powerline PRO Softener is just one way to enjoy better water Contact your Kinetico Dealer for more information about additio...

Page 4: ...he water softener provides a Regeneration process whereby brine solution enters the mineral tank driving off the collected hardness ions and replenishes the surface of the resin beads with more sodium...

Page 5: ...from lime and iron buildup Replace piping that has heavy lime and or iron buildup If piping is clogged with iron install a separate iron filter unit ahead of the water softener By pass Valves Always...

Page 6: ...button Example A To accept the digit value press the Menu Enter button Once A M or P M is accepted the next menu item will flash 4 To set Hardness an H will appear to enter compensated hardness in gra...

Page 7: ...em settings will be affected Starting Extra Regeneration Cycle 1 To Start Delayed Extra Cycle Example 1 If Days Remaining Until Next Regeneration does not read 000 press and hold the Set Change button...

Page 8: ...ver it Resin Fouling Call Dealer Find out how to confirm it Clean the resin and prevent future fouling Poor distribution channeling uneven bed surface Call Dealer Check backwash flow Regenerate more f...

Page 9: ...stuck Check brine tank for leaks Water pressure is too low Line pressure must be at least 20 psi Brine line injects air during brine draw Check brine line connections for air leaks Internal control l...

Page 10: ..._________________________ __________________________________________________ __________________________________________________ __________________________________________________ _____________________...

Page 11: ..._____________________________________ __________________________________________________ __________________________________________________ __________________________________________________ _________...

Page 12: ...HQ KineticoWater Kinetico makes an entire line of water treatment products designed to handle almost any water problem For more information contact your authorized Kinetico Dealer or visit our website...

Reviews: