6
Electrical Metered Valve Setting
Set-up Procedures
System Adjustments Using Push Button/Display Interface
NOTE:
Changing any setting could affect the operation of your system. Consult your local
Dealer before making any adjustments
Main Menu
12
:
00
MENU / ENTER
BUTTON
SET / CHANGE
BUTTON
1. To enter Main Menu, press the
Menu/Enter
button. (Time of Day will flash.)
2. To set the
Time of Day
, press the
Set/Change
button. (First digit will flash.)
Example
(12
:
00)
- To change digit value, press the
Set/Change
button.
- To accept the digit value, press the
Menu/Enter
button.
- Next digit will flash to begin setting.
- Once the last digit display is accepted, all digits will flash.
3. To set
A.M.
or
P.M.
, press the
Menu/Enter
button.
- To change digit value, press the
Set/Change
button. Example
(A)
- To accept the digit value, press the
Menu/Enter
button.
- Once
A.M.
or
P.M.
is accepted, the next menu item will flash.
4. To set
Hardness
an H will appear to enter compensated hardness in grains per
gallon (gpg). Default setting is 25 gpg.
Example
(H
-
25)
NOTE:
Note: If the water contains iron and / or manganese, multiply the total parts per
million (ppm) by “four” (4) and then add to the grains per gallon (gpg) of hard-
ness. Use this COMPENSATED HARDNESS level when programming the regener-
ation frequency.
5. To Exit Main Menu, press the
Menu/Enter
button.
NOTE:
If no buttons are pressed for 60 seconds, the Main Menu will be exited automatically.
System Adjustments Using Smart Phone/Tablet Interface
NOTE:
Changing any setting could affect the operation of your system. Consult your local
Dealer before making any adjustments
To take advantage of the bluetooth interface, this feature must be set up on
compatible Bluetooth-enabled smart phones or tablets.
Summary of Contents for 17214