SECTION 1
INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Main injector : (1 off)
Bray Injector Cat 82 – size 420 (NG)
Pilot Type :
Copreci ODS 21100 / 141
Max. Gross Heat Input :
6.9 kW
Min. Gross Heat Input :
3.5 kW
Gas Rate :
0.634 m3/hr (High)
0.325 m3/hr (Low)
Cold Pressure :
G20 20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition :
Integral to gas valve
Electrode Spark Gap :
4.0mm
Packed Weight Combustion Chamber : 33.0 kg
Fig. 1
Top View of Combustion
Side View of Combustion
Chamber
Chamber
3
795 mm
750 mm
353 mm
375mm
Flue
Spigot
138mm
550mm
480mm
138mm CRS
353mm
436mm
135mm
Flat Edge of Flue Termination
must be installed facing front
of product only.
Minimum 50mm
clearance required
around flue outlet
as shown by dotted
line