SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a CORGI
registered engineer.
This is a condition of the Kinder Fires extended
guarantee schemes.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for a positive up-draught in the
chimney.
The condition of the log pieces should be checked and
if necessary the whole
set should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of
access.
After any servicing work a gas tightness check must always be
carried out.
Manual Control Fires – For Diagrams refer to Section 2
4.1
Removing the MC Burner Assembly
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the “Concept” fascia. Lift the fascia out of the way and put it in
a safe location. Remove the loose log pieces from the fuel bed
Remove the front ceramic from the rail. Unscrew the 4 screws which
retain the glass brackets and remove the glass panel.
4.1.3
Isolate the gas supply and remove the inlet pipe from the appliance
inlet elbow. Unscrew and remove the screw which retains the
burner. Remove the burner assembly from the fire.
4.1.4
To refit the burner assembly. Push the base of the control panel fully
into the fire and secure with the retaining screw Refit the gas supply
pipe and carry out a gas tightness test. Refit the pilot heat shield
then refit the log pieces referring to section 3 for the correct
log layout. The fascia can now be re-positioned.
4.2
Removing the Piezo Igniter
4.2.1
Remove the burner assembly as in section 4.1
4.2.2
Disconnect the ignition lead from the piezo and unscrew the
retaining nut on the rear of the control panel. Withdraw the piezo from
the front of the control panel. Reassemble in reverse order and carry
out a gas tightness test.
27