kincrome KP87006 Manual Download Page 8

8

UNIVERSAL BATTERY CHARGER &  

MAINTAINER  

12V 25 AMP

3. Connect the battery charger to Mains Power (220-240Vac)
•  The charger will automatically start when AC power is connected and switched ON. 
•  IMPORTANT: Please make sure the correct Battery Type and your desired Charge Rate 

is selected to suit your battery by pressing the Select Buttons within the first 5 minutes 
of charging. For Example do not charge a Gel Battery on the Calcium Battery Type  
setting as this may damage your battery and / or reduce your battery life. 

Note: If the Fault Indicator LED illuminates RED, please check your connections as it’s 
likely that the Positive and Negative Leads are reversed.

4. The Charging Process:
•  Qualification - Battery Condition Check
 

When the charger is first switched ON it checks the battery condition to determine 
whether the battery needs reconditioning. During this qualification process it checks 
the internal impedance and initial Voltage of the battery and it will determine how 
much charge current, if any that the battery will accept. 

•  Automatic Enhanced Battery Rejuvenation - BLUE Bulk LED Flashing Fast 

If the initial qualification detected that the battery was in poor condition, the patented 
rejuvenation process will begin automatically. During the rejuvenation process a 
high Voltage equalising and peak pulse reconditioning charge is used to repair the 
sulphated battery. This unique patented feature will break down and dissolve the  
lead-sulphate crystal build up on the battery plates which will extend the life of your 
battery. It can also balance out high concentrations of acid. The equalisation Voltage 
will be 16V maximum. If the charging current detected is less than 0.1A after 24 hours, 
the Rejuvenation process will time out.

•  Manual  Enhanced Rejunvenation Mode 

To manually rejuvenate your batteries, simply press and hold the Battery Type button 
for 3 seconds until the BLUE Bulk LED flashes rapidly. This mode will last for 24 Hours. 
To stop rejuvenation mode, press and hold the Charge Rate button for 3 seconds until 
the BLUE Bulk LED stops flashing rapidly.  
Important Note: Please check your Battery Type and Charge Rate selection to ensure 
you haven’t accidentally changed these settings.

•  Soft Start Charging - BLUE Bulk LED Flashing Slow 

Gently charges the battery using a reduced charge output until the battery Voltages 
reaches 11V. If the battery Voltage doesn’t reach 11V within 6 hours, the safety timer 
protection will stop the unit from charging and the RED Fault LED and BLUE Bulk LED 
will start flashing.

•  Bulk Charging - BLUE Bulk LED ON

 (Charge Voltage depends on battery type selection)

 

Uses the maximum selected charge output until the battery Voltage reaches the 
Charge Voltage specified for the selected Battery Type.  If the battery Voltage doesn’t 

KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd   8

18/04/2018   2:15 PM

Summary of Contents for KP87006

Page 1: ...NATION RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED BATTERY REJUVENATION RECOND...

Page 2: ...15 to 50 C Storage Temperature 25 to 85 C Operating Humidity 90 RH Max Temperature Compensation 25mV C C Dimensions 279 x 141 x 67mm Weight 2kg Approvals CE AS NZS EMC Table of Contents Know Your Pro...

Page 3: ...r on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circuit the battery...

Page 4: ...ently connected all year round The intelligent charger will monitor the battery Voltage and will maintain it at peak performance with a special pulse charge during long term maintenance Short circuit...

Page 5: ...CHARGING ON BULK CHARGING POWER SUPPLY ON UNIT IN POWER SUPPLY MODE 25A LED WILL ALSO BE ON NOTE IF THE FAULT LED IS ON WHILE IN POWER SUPPLY MODE THIS INDICATES EITHER SHORT CIRCUIT REVERSE POLARITY...

Page 6: ...ON This prevents the charger from being damaged if the positive and negative crocodile clips or the optional ring terminals accidently touch each other while the charger is turned ON ECO MODE This Ki...

Page 7: ...e RED Crocodile clip or ring terminal to the battery terminal Connect the BLACK Crocodile clip or ring terminal to the battery terminal Fig 1 CAUTION The Temperature Sensor should be connected to the...

Page 8: ...ning charge is used to repair the sulphated battery This unique patented feature will break down and dissolve the lead sulphate crystal build up on the battery plates which will extend the life of you...

Page 9: ...kly during the analysis mode this means the battery is probably faulty If the battery analysis failed the GREEN Full LED flashing Float Mode Full GREEN LED ON This stage allows you to keep the charger...

Page 10: ...10 UNIVERSAL BATTERY CHARGER MAINTAINER 12V 25 AMP CHARGING CURVE Can also be activated manually KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1 0 indd 10 18 04 2018 2 15 PM...

Page 11: ...Battery has a damaged cell Over temperature protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t co...

Page 12: ...entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods f...