kincrome KP87006 Manual Download Page 3

3

UNIVERSAL BATTERY CHARGER &  

MAINTAINER  

12V 25 AMP

 

IMPORTANT SAFETY ADVICE AND WARNINGS

•  The charger is designed to charge and maintain conventional lead-acid batteries only

(VRLA), AGM, CALCIUM, GEL & WET. Not suitable for lithium type batteries.

•  Always refer to the battery manufacturers specifications and recommendations if you’re 

unsure of your battery charging requirements. Eg. Such as removing or not removing 
cell caps whilst charging, battery type, maximum charge rate etc..

•  Explosive gases may escape from the battery during charging so please ensure the 

battery is charged in a well ventilated area.

•  This charger is designed for indoor use only and should never be exposed to water,  

rain, snow, liquids etc.

•  Do not attempt to use the charger if it has been dropped or damaged.
•  Do not attempt to use the charger if the cables or plugs are damaged.
•  If battery acid contacts your skin or clothing, wash immediately with soap and water. If acid 

enters your eye, immediately flush the eye with running cold water for at least 10 minutes 
and seek medical attention. Someone should always be within range of your voice.

•  Never attempt to charge a damaged battery, frozen battery or non rechargeable battery. 
•  Never place the charger on the battery or battery on the charger. 
•  When working with lead-acid batteries, remove personal metal items such as rings, 

bracelets, necklaces, watches and make sure you don’t short circuit the battery termi-
nals with any type of metal tool or piece of jewellery as this will cause an explosion. You 
can wrap your spanner with insulation tape to minimise the risk of a short circuit.

•  NEVER smoke, use an open flame or create sparks near a battery or charger during 

charging operation as this may cause an explosion and explosive gases.

•  Do not disassemble the charger. Take it to a qualified and authorised person for repair.
•  If using a generator, you must ensure you use a surge protector to protect the charger 

from Voltage spikes.

•  The charger must not be used or played with by infirm persons or children. Also keep it 

away from any pets.

MAIN FEATURES 

•  100% automatic smart battery charger & maintainer with reconditioning.
•  Power Supply Mode
•  Temperature Compensation (Sensor attached to Negative battery clamp)
•  The battery charger is easy to use and requires NO technical experience.
•  Fully microprocessor controlled with safety timers at every stage.
•  Battery condition analysis.
•  Selectable battery type.
•  Selectable charge rate / mode.
•  Patented battery rejuvenation (reconditioning).
•  Battery Voltage retention analysis.
•  Pulse charge for long term maintenance.

KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd   3

18/04/2018   2:15 PM

Summary of Contents for KP87006

Page 1: ...NATION RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED BATTERY REJUVENATION RECOND...

Page 2: ...15 to 50 C Storage Temperature 25 to 85 C Operating Humidity 90 RH Max Temperature Compensation 25mV C C Dimensions 279 x 141 x 67mm Weight 2kg Approvals CE AS NZS EMC Table of Contents Know Your Pro...

Page 3: ...r on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circuit the battery...

Page 4: ...ently connected all year round The intelligent charger will monitor the battery Voltage and will maintain it at peak performance with a special pulse charge during long term maintenance Short circuit...

Page 5: ...CHARGING ON BULK CHARGING POWER SUPPLY ON UNIT IN POWER SUPPLY MODE 25A LED WILL ALSO BE ON NOTE IF THE FAULT LED IS ON WHILE IN POWER SUPPLY MODE THIS INDICATES EITHER SHORT CIRCUIT REVERSE POLARITY...

Page 6: ...ON This prevents the charger from being damaged if the positive and negative crocodile clips or the optional ring terminals accidently touch each other while the charger is turned ON ECO MODE This Ki...

Page 7: ...e RED Crocodile clip or ring terminal to the battery terminal Connect the BLACK Crocodile clip or ring terminal to the battery terminal Fig 1 CAUTION The Temperature Sensor should be connected to the...

Page 8: ...ning charge is used to repair the sulphated battery This unique patented feature will break down and dissolve the lead sulphate crystal build up on the battery plates which will extend the life of you...

Page 9: ...kly during the analysis mode this means the battery is probably faulty If the battery analysis failed the GREEN Full LED flashing Float Mode Full GREEN LED ON This stage allows you to keep the charger...

Page 10: ...10 UNIVERSAL BATTERY CHARGER MAINTAINER 12V 25 AMP CHARGING CURVE Can also be activated manually KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1 0 indd 10 18 04 2018 2 15 PM...

Page 11: ...Battery has a damaged cell Over temperature protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t co...

Page 12: ...entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods f...

Reviews: